Üreticisi Fiber Optik Sıcaklık Sensörü, Sıcaklık İzleme Sistemi, Profesyonel OEM/ODM Fabrika, Toptancı, Tedarikçi.özelleştirilmiş.

E-posta: web@fjinno.net |

Bloglar

ct'yi kelepçele

Ürüne Genel Bakış

Clamp on CT (Clamp-on Current Transformer) is an innovative split-core current measurement device designed for measuring 1-200 ampere AC currents. Featuring plug-and-play design, it easily clamps around conductors without power disconnection, providing standard 0.333V voltage output proportional to primary current RMS value.

Temel Avantajlar

  • Split-core design for convenient installation
  • Wide measurement range: 1-200A AC
  • High accuracy measurement with minimal error
  • UL certified, complying with global safety standards
  • High isolation between primary and secondary circuits

Product Özellikler

Teknik Özellikler

Feature Item Teknik Parametreler Advantage Description
Ölçüm Aralığı 1-200A AC Covers small to large equipment monitoring needs
Output Signal 0.333V voltage output Stable and reliable, easy signal processing
Doğruluk Derecesi Yüksek doğruluk, low error Provides accurate and reliable measurement results
Frekans Tepkisi 50/60Hz compatible Suitable for global power system standards
Çalışma Sıcaklığı Geniş sıcaklık aralığı Adapts to various environmental conditions
Kurulum Yöntemi Split-core clamp type No power disconnection required, plug and play

Performance Features

Stable Output Signal

0.333V standard voltage output maintains precise proportional relationship with primary current RMS value, unaffected by environmental temperature and electromagnetic interference.

Frequency compatibility perfectly supports 50Hz and 60Hz power systems with good harmonic adaptation, ensuring measurement accuracy in complex electrical environments.

Temperature resilience features excellent temperature compensation design, maintaining stable performance across wide temperature ranges, suitable for indoor and outdoor installation environments.


Product Faydalar

Installation and Usage Benefits

Benefit Item Specific Performance Uygulama Değeri
Kolay Kurulum Split-core clamp design, no power disconnection Reduces installation cost and risk
Plug and Play No configuration required, ready to use Quick deployment, saves time
Multi-Purpose Suitable for various application scenarios One product meets multiple needs
Uygun Maliyetli High value solution Reduces total ownership cost

Quality and Certification Benefits

UL Recognition

UL certified with North America’s most authoritative safety certification, ensuring products meet strict safety standards in design, malzemeler, and manufacturing processes.

CE compliance meets EU health, emniyet, and environmental requirements, freely marketable in European markets.

RoHS compliant with environmentally friendly design, containing no harmful substances, reflecting sustainable development principles.

Precise measurement uses high-quality core materials and precision winding processes, ensuring measurement errors are controlled within minimum range.


Uygulamalar

Trafo İzleme

Monitoring Object Uygulama Açıklaması Monitoring Value
Transformer Load Current Real-time monitoring of primary/secondary current Prevents overload, extends equipment life
Fan Motor Current Cooling fan operation status monitoring Prevents transformer overheating accidents
Pump Motor Current Oil circulation pump operation monitoring Ensures cooling system normal operation
OLTC Motor Current On-load tap changer motor monitoring Ensures voltage regulation function normality

Şalt donanımı/Breaker İzleme

Phase Current Measurement

Gerçek zamanlı izleme of three-phase current balance, timely detection of phase imbalance, phase loss, and other abnormal conditions.

Motor current monitoring tracks operating mechanism motors, auxiliary motors, and other critical equipment operating status.

Heater current detection ensures outdoor equipment anti-condensation systems work properly, maintaining insulation performance.

Automation and Control

Koruma Sistemleri

Protection system current measurement provides accurate current signals for relay protection devices, implementing overcurrent, differential, and other protection functions.

Industrial control provides current feedback for PLC/DCS systems, enabling load monitoring and equipment diagnosis.

Energy management provides precise current data supporting power calculation and energy consumption statistical analysis.


Teknik Özellikler

Basic Parameters

Parameter Item Teknik Şartname Remarks
Ölçüm Aralığı 1-200A AC AC current measurement
Output Voltage 0.333V Proportional to primary current RMS value
Frekans Aralığı 50/60Hz. Supports global power standards
Isolation Voltage High isolation Ensures safety and reliability
Çalışma Sıcaklığı Geniş sıcaklık aralığı Adapts to various environments
Kurulum Yöntemi Split-core clamp type No power disconnection installation

Certification Standards

  • UL Recognition: Complies with North American safety standards
  • CE Sertifikası: Meets European Union requirements
  • RoHS Compliant: Environmentally friendly materials, no harmful substances

Installation Guide

nedir Clamp on CT?

Clamp on CT is a current transformer with split-core design that installs around conductors using clamp method, measuring AC current through electromagnetic induction principle and outputting voltage signals proportional to current.

Do you clamp CT on live or neutral?

Correct Installation Position

Proper installation location: Should clamp CT on live wire (hot conductor), not neutral wire. Üç fazlı sistemlerde, clamp on phase lines; in single-phase systems, clamp on hot line to ensure measurement accuracy.

ne işe yarar CT clamp reading mean?

CT clamp reading represents current values measured through current transformer, output as 0.333V voltage form, requiring conversion coefficients to obtain actual current values, providing continuous real-time current monitoring capability.

Kurulum Adımları

Step-by-Step Process

  1. Select installation position: Identify measured conductor, choose appropriate clamp location
  2. Open transformer: Separate split-core transformer halves
  3. Clamp conductor: Position conductor at transformer center, ensure perpendicular passage
  4. Close transformer: Align and clamp halves tightly, ensure tight contact surfaces
  5. Connect output: Connect output cables to monitoring or control equipment

Precautions

Safety and Accuracy Notes

  • Ensure single conductor passes through transformer window
  • Conductor should be positioned at window center
  • Avoid multiple conductors passing through simultaneously
  • Regularly check clamp fastening status
  • Secondary side must not operate open-circuit

nedir Current CT Clamp?

Split-Core Current Transformer Design

Split-core current transformer for the measurement of AC currents from 1 ile 200 Amps. The Clamp-On CT easily snaps around the conductor and is ideal for installation on electrical wiring. It has output in voltage form, 0.333V that is proportional to the RMS value of the primary current.

Temel Özellikler

High Isolation Performance

High isolation between primary and secondary circuits ensures operator and equipment safety, maintaining safe potential even during primary circuit faults.

Kompakt tasarım, Plug and Play philosophy throughout product development, adapting to modern electrical equipment space constraints while reducing installation complexity.

Cost-Effective Solution for variety of applications enables one product to meet multiple application requirements, significantly reducing procurement and inventory costs.

High accuracy and durable construction using quality core materials and precision manufacturing processes ensures long-term reliable performance.


Choose professional Clamp on CT for accurate, güvenli, and reliable current monitoring solutions!

sorgu

Fiber optik sıcaklık sensörü, Akıllı izleme sistemi, Çin'de dağıtılmış fiber optik üreticisi

Floresan fiber optik sıcaklık ölçümü Floresan fiber optik sıcaklık ölçüm cihazı Dağıtılmış floresan fiber optik sıcaklık ölçüm sistemi

Önceki:

Sonraki:

Mesaj bırakın