Why does the bus duct need temperature measurement
Closed busbar trunking (abbreviated as busbar trunking) is widely used in power supply systems of high-rise buildings and buildings. But with the rapid increase in electricity consumption, the heating of the bus duct is particularly severe, especially at the connection head, which seriously affects the normal operation of the bus duct and requires real-time monitoring of electricity safety. Traditional temperature sensing cables have serious defects in the setting, quantification, nafasi, and reusability of temperature alarm points, which cannot meet the needs of production process management. Hata hivyo, high-precision point type thermometers or thermocouples cannot solve the needs of linear and continuous monitoring.
What are the advantages of fiber optic iliyosambazwa mifumo ya kipimo cha joto
The mfumo wa ufuatiliaji wa joto la fiber optic iliyosambazwa adopts a brand new design, with good performance indicators and system stability. This system is developed based on the principles of backward Raman scattering and optical time-domain reflection (OTDR) nafasi, and has functions such as optical signal generation, spectral analysis, ubadilishaji wa photoelectric, ukuzaji wa ishara, na usindikaji. The system uses dedicated temperature sensing optical cables as temperature sensors, kuunganisha kompyuta, mawasiliano ya fiber optic, kuhisi fiber optic, optoelectronic control and other technologies. It has inherent safety, upinzani wa kutu, na haiathiriwi na kuingiliwa kwa sumakuumeme. It continuously monitors long-distance and large-scale environmental temperature information.

Characteristics of Distributed Fiber Optic Bus Channel Temperature Monitoring System
Using distributed fiber optic temperature sensing equipment to sense cable temperature and position information for signal detection and transmission, bila kupata utambuzi wa umeme na usalama wa ndani wa kuzuia mlipuko;
Kwa kutumia kipengele cha halijoto cha juu kilichosambazwa cha nyuzinyuzi kama kitengo cha kipimo, na teknolojia ya hali ya juu na usahihi wa kipimo cha juu:
Kebo za macho zinazoweza kuhisi halijoto zina safu ya joto ya uendeshaji ya muda mrefu -40 ℃ kwa 150 ℃, na upeo wa 200 ℃, na anuwai ya maombi;
Adopting a detector single loop measurement method, simple installation and low cost; Can reserve spare cores;
Onyesho la wakati halisi la halijoto katika maeneo mbalimbali, na uwezo wa kuonyesha data ya kihistoria na kubadilisha curves, pamoja na mabadiliko ya wastani ya joto:
Mfumo una muundo wa kompakt, ufungaji rahisi, na matengenezo rahisi;
Kupitia programu, onyo tofauti na maadili ya kengele yanaweza kuwekwa kulingana na hali halisi; Mbinu za kengele ni tofauti, ikiwa ni pamoja na kengele ya joto ya mara kwa mara, kengele ya ongezeko la joto, na kengele ya tofauti ya joto.
Kupitia programu, data inaweza kuulizwa: hoja kwa hoja, swali la rekodi ya kengele, swala la muda, swala la data ya kihistoria, na uchapishaji wa ripoti.
On site installation diagram of distributed fiber optic bus duct
![]() |
![]() |
![]() |
Distributed fiber optic temperature measurement software interface
Provide a user-friendly and easy-to-use fiber optic temperature monitoring application software. The software mainly includes functional modules such as temperature monitoring, fire alarm, and visual display.
Temperature curve display
The system can display the real-time temperature distribution curve of the entire optical cable, and when there is an abnormal temperature at a certain location, the curve can show whether the temperature at that location increases or decreases.
Historical temperature statistics
Provide historical temperature data statistical analysis function, provide temperature change trends, ikijumuisha:
(1) The temperature distribution curve at different positions of the cable at a certain moment;
(2) The temperature change curve of a cable at a certain point on a certain day;
(3) The temperature change curve at a certain point of the cable during a certain period of time;
(4) The curve of the highest temperature change on a certain day.
Kengele ya juu ya joto
Provide various flexible fire alarm methods such as fixed temperature, kupanda kwa joto, and regional temperature difference, and the alarm parameters can be graded and set by region. When the measured temperature exceeds the threshold temperature, the system will automatically emit alarm signals such as sound, Taa za kiashiria cha LED, text, and images. If multi-level temperature alarm (such as initial alarm at 30 ℃, pre alarm at 40 ℃, and measures taken at 50 ℃) and temperature rise rate can be set, temperature correction can be made according to different environments. The set value of temperature rise rate can be determined by on-site monitoring.
Visual interface
Provide a visual display interface that maps the fiber optic position to the image through a graphical configuration module. Once a temperature anomaly occurs at a certain point of the fiber optic, the alarm information is directly displayed on the image, making it visually appealing.
![]() |
![]() |
![]() |
Vihisi joto vya INNO fiber optic ,mifumo ya ufuatiliaji wa joto.