Leveraging long-range continuous monitoring, strong odporność na zakłócenia elektromagnetyczne (EMI), odporność na korozję, wysoka czułość, I real-time response, distributed fiber-optic sensing is well-suited to complex environments jak na przykład wysoka temperatura, wysokie ciśnienie, corrosive media, I strong EMI. It plays a critical role in safe production, asset maintenance, I risk early warning.
Distributed Fiber-Optic Temperature Sensing (DTS)
Zalety techniczne
| Korzyść | What It Means | Typical Figure / Notatka |
|---|---|---|
| Long-range continuous monitoring | Continuous temperature profiles over extended assets and lines | Aż do kilometrów |
| Strong anti-interference I odporność na korozję | Non-metallic fiber tolerates acid/alkali, corrosive media, I strong EMI | Suitable for przeciwwybuchowy środowiska |
| Wysoka czułość | Detects subtle temperature changes | Temperature resolution up to 0.01 °C |
| Passive monitoring | No local power, no spark risk | Enhances intrinsic safety |
Why It Fits Industrial Sites
| Site Challenge | Fiber-Optic Benefit | Wynik |
|---|---|---|
| Large campuses, dispersed pipelines/equipment | Builds a wide-area monitoring network | End-to-end coverage across the site |
| Strong EMI (silniki, pump sets), corrosive media | Non-metallic fiber withstands harsh environments | Stable, interference-free measurements |
| Hazardous leaks, equipment overheating | Seconds-level response, fine 0.01 °C rezolucja | Rapid detection and warning |
| Explosion-proof areas | Passive sensing, no power at the field cable | Compliant with bezpieczeństwo wewnętrzne wymagania |
Proactive Early Warning + Precise Localization + Real-time Monitoring — Product Features
- High performance z fine spatial resolution I long measurement distance; supports high-precision localization I sampling.
- High integration with a compact core module.
- Wide-voltage power input I low power consumption.
- Obsługuje laser safety classes.
- Seconds-level alarm response; real-time synchronous updates of tens of thousands of temperature points. Any point with an abnormal temperature triggers a timely warning within seconds.
- Rich interfaces: RJ45 Ethernet, RS485; protocols include Modbus RTU, Modbus TCP, JSON, I zwyczaj; multiple relay channels for easy third-party integration.
- Obsługuje fixed-temperature alarms, differential-temperature alarms, alarmy szybkości narastania, average-value alarms, I fault alarms.
- Uses standard telecom multimode fiber; flexible routing unaffected by terrain or harsh conditions (high/low temperatures, wilgotność, pył, toxic/corrosive gases, flammable/explosive środowiska, strong EMI). The fiber itself is pasywny and requires no power; nadaje się do długodystansowe deployment in complex, irregular terrain with no on-site power I no network.
Key Performance Snapshot
| Parametr | Capability | Notatki |
|---|---|---|
| Rozdzielczość przestrzenna | Fine resolution | Enables precise localization along the fiber |
| Monitoring distance | Long-range | Up to kilometers-scale lines |
| Czas reakcji | Seconds-level | Rapid alarm and update |
| Temperature resolution | Aż do 0.01 °C | High sensitivity to small changes |
| Interfaces / Protokoły | RJ45, RS485; Modbus RTU/TCP, JSON, zwyczaj | Multiple relays for external signaling |
| Moc | Wide-voltage, low power | Efficient and adaptable |
| Laser safety | Standards-compliant classes | Safe operation |
Proactive Threshold-based Early Warning
1) Temperature Parameters and Alarm Thresholds
Configure alarm thresholds in the monitoring software in line with wymagania I standardy bezpieczeństwa. Na przykład, when temperature exceeds the upper limit of 80 °C, the system issues a Level-1 alarm automatically. If the temperature rises sharply in a short time and the rate-of-rise exceeds a set value (np., 5 °C/min), A Level-2 alarm is triggered, enabling proactive intervention—shifting from after-the-fact handling Do before-the-fact prevention.
2) Dokładny, High-Accuracy Spatial Localization
W pipeline leak monitoring, the system rapidly determines the exact location of the leak, saving troubleshooting time for maintenance teams and reducing losses caused by leakage.
3) W czasie rzeczywistym, Full-Coverage Monitoring and Visualization
The system runs 7×24 z no blind spots across all areas covered by the installed sensing fiber. Whether during busy daytime production or at night with minimal staffing, it continuously safeguards plant assets. A visualized real-time dashboard presents monitoring data intuitively, allowing operations and maintenance personnel to view the plant’s status anytime, gdziekolwiek, with clear situational awareness.
Technology Leadership and Service
- Technology leadership: Proprietary core technologies deliver internationally advanced performance in dokładność pomiaru, localization accuracy, I monitoring distance.
- Wysoka niezawodność: Single-board design with three-proof treatment for long-term stability; products certified by ISO three-system and other international standards to ensure stable and reliable operation.
- Customized service: Tailored solutions to enterprise scale, process characteristics, I facility layout, with end-to-end support from design and commissioning to operacje & konserwacja.
- Ekonomiczne: Compared with traditional czujniki punktowe, distributed fiber reduces device count I wiring costs; early warning lowers incident rates, reducing naprawa I przestój losses for a higher long-term Zwrot z inwestycji.
Value Highlights
| Wymiar | Opis | Uderzenie |
|---|---|---|
| Dokładność & Zakres | Advanced measurement/localization accuracy, long-distance coverage | Trusted detection across large facilities |
| Niezawodność | Ruggedized design, ISO-certified processes | Stable operations and reduced maintenance |
| Personalizacja | Projekt, instalacja, uruchomienie, and O&M support | Faster deployment, better fit to site needs |
| Koszt & Zwrot z inwestycji | Fewer devices and cables; fewer incidents | Lower TCO and higher long-term ROI |
Alarm Modes Summary
| Alarm Mode | Zamiar | Typowe zastosowanie |
|---|---|---|
| Fixed-temperature alarm | Triggers when temperature exceeds a set threshold | Overheat protection, hot-spot detection |
| Differential-temperature alarm | Detects abnormal temperature differences | Sectional comparison along pipelines |
| Rate-of-rise alarm | Detects rapid temperature increases | Early fire/leak indication |
| Average-value alarm | Monitors mean temperature over a window | Process stability monitoring |
| Alarm awarii | Indicates sensor/system anomalies | Maintenance and reliability |
Connectivity and Protocols
| Interfaces | Protokoły | Integracja |
|---|---|---|
| RJ45 Ethernet, RS485 | Modbus RTU, Modbus TCP, JSON, zwyczaj | Multi-relay outputs for third-party systems |
Sensor and Deployment
The system employs standard telecom multimode fiber to jest flexible to install and unaffected by terrain or harsh environments. The fiber is pasywny, requiring no local power, making it ideal for długodystansowe I irregular terrain deployments where on-site moc Lub network is unavailable.
| Środowisko | Tolerancja | Korzyść |
|---|---|---|
| High/Low temperature | Stable sensing along the fiber | Reliable in extreme climates |
| Wilgotność / Dust | Niemetalowe, sealed fiber path | Reduced degradation and drift |
| Toxic/Corrosive gases | Corrosion-resistant materials | Długa żywotność |
| Flammable/Explosive areas | Pasywny, no sparks | Enhanced safety compliance |
| Strong EMI | Optical signal immune to interference | Dokładny, stable readings |
Światłowodowy czujnik temperatury, Inteligentny system monitorowania, Producent rozproszonych światłowodów w Chinach
![]() |
![]() |
![]() |