Kaedah terbaik untuk pemantauan suhu dalam suis adalah menggunakan sensor gentian optik

Point type penderia suhu gentian optik can be used for safety monitoring of power equipment. On the basis of effectively maintaining application quality, temperature sensing elements can be used to constrain the measurement process. Due to the high measurement accuracy and simple principle of these sensors, which can improve the timeliness of operation, they are widely used in power equipment monitoring projects to optimize the actual level of temperature measurement and analysis.

Characteristics of Fiber Optic Sensors

Fiber optic sensors themselves have characteristics such as insulation and resistance to electromagnetic interference, which can ensure the safety of the monitoring process, and have outstanding corrosion resistance and high temperature resistance. Penggunaannya pada medan elektrik DC tinggi boleh meningkatkan pengukuran suhu sentuhan dengan berkesan, dengan ketepatan pengukuran yang tinggi, dan mewujudkan rangkaian pengukuran yang sepadan, meletakkan asas untuk pemantauan automasi seterusnya operasi peralatan kuasa.

Dalam proses aplikasi teknologi pengesan suhu gentian optik, sama ada di dalam dan luar negara, tumpuan adalah pada penyelidikan sensor dan pengurusan suhu gentian optik. Oleh itu, penderia suhu parut gentian optik telah menjadi kunci kepada projek penyelidikan dalam teknologi pengesan suhu gentian optik. Dalam sistem pengukuran suhu teragih gentian optik, penyelidikan mengenai teknologi pengesan suhu gentian optik perlu disepadukan dengan pencegahan kebakaran, kawalan suhu berbilang titik, dan projek lain untuk analisis komprehensif, but its overall cost is relatively high.

The basic temperature measurement principle of point type fiber optic temperature sensors in practical applications is that the critical edge of the semiconductor absorption spectrum will change with temperature and move accordingly. It can establish effective analysis and judgment of the degree of change after the semiconductor chip undergoes light intensity processing. Selain itu, the absorption rate of semiconductor media is directly related to the bandgap width of the semiconductor during the process of light absorption. After the temperature changes, thermal expansion and temperature changes will affect the vibration state of the crystal, causing changes in the actual width parameter of the bandgap and resulting in abnormal absorption spectra.

Under certain conditions, ketebalan pencahayaan sumber cahaya berbeza-beza. Keamatan cahaya yang diunjurkan perlu diukur untuk parameter tertentu dengan bantuan It ddt RR I α α − − −=1 e (1) e22. Antaranya, R mewakili pekali pantulan kuasa keseluruhan sistem pencahayaan sumber cahaya, yang berkadar dengan indeks biasan, pekali kepupusan, dan sudut tuju bahan; D mewakili ketebalan sebenar keseluruhan struktur semikonduktor; α mewakili pekali penyerapan bahan semikonduktor itu sendiri. Dengan menggabungkan data ukuran sebenar, adalah mungkin untuk menganalisis tahap sebenar sistem yang sepadan dengan berkesan, dan dengan menggabungkan hubungan antara fungsi penentuan panjang gelombang sumber cahaya, calculate the integral over the entire wavelength range. Maksudnya, in practical operation, selecting an incident broadband light source and matching photodiodes can effectively calculate and analyze the transmitted light intensity, and the relevant parameters can also show different trends with changes in environmental temperature, effectively improving the overall efficiency of temperature detection work.

Pelaksanaan Sensor Gentian Optik System in Power System Detection

In the hardware implementation of power systems, the operational level of switchgear is crucial, and technicians need to integrate circuit breakers to ensure that mobile carts and switchgear can play their actual value. Antaranya, the high-voltage switchgear itself has 6 kenalan, one distributed on each of the three phases on the upper and lower sides, which can effectively improve the reliability of system operation and enable real-time monitoring and temperature measurement with the help of contacts. Oleh itu, it is necessary to improve the probe and circuit signal processing facilities during the temperature monitoring process of the high-voltage switchgear in the system, and to achieve the following points.

Pertama sekali, select the light source. After the light is emitted from the light source, the transmittance intensity will gradually change with temperature changes through the action of the probe. With the help of a point type sensor suhu gentian optik, the intensity of the transmitted light can be monitored for temperature to ensure the implementation of the work. Oleh itu, technicians need to constrain the measurement range of sensors in the selection of light sources, and judge based on the temperature change of the critical edge of the absorption spectrum to effectively obtain a wider spectral width parameter. It should be noted that in terms of selecting the wavelength of the light source, sufficient parameter considerations should be made in conjunction with the absorption edge, and the parameters should be controlled between 864-908 nm to select more suitable parameters, laying the foundation for the comprehensive development of detecting light intensity expansion and center wavelength processing work.

Kedua, the probe design work, combined with the application structure and principle of the sensor itself, applies it to the contact processing of high-voltage switchgear in the power system, conducts temperature testing on high-voltage cable joints, and ensures that it can provide basic parameters for sensor installation work. In the process of designing probes, it is necessary to analyze and determine the volume and thermal balance parameters of the probe. Secara amnya, copper materials with good thermal conductivity are chosen to improve the timeliness of the processing mechanism to a certain extent.

Ketiga, signal processing circuit design. In sensor signal processing, it is necessary to determine the core unit based on actual requirements, effectively integrate the microcontroller structure, use high-performance and low-power 8-bit AVR microcontrollers to effectively determine relevant parameters, reasonably improve the control of memory, provide guarantees for obtaining hardware interface circuits, and integrate RISC simplified instructions to ensure the integration effect of the structure and optimize the system programming effect.

Application of Fiber Optic Temperature Measurement System Software

In the power equipment monitoring system, combined with the efficiency and overall application level of sensors, in addition to overall management of hardware structure, it is also necessary to improve the software system to ensure that the corresponding system components can lay the foundation for the smooth implementation of safety monitoring work.

Pertama sekali, the signal acquisition and control software system mainly captures signals in a timely manner, filters and summarizes signal information for subsequent development of corresponding action instructions. It should be noted that in the signal acquisition, pemprosesan, and control system, attention should be paid to the authenticity of data information in order to achieve comprehensive supervision and control quality.

Kedua, the structure of signal filtering software mainly involves analyzing and determining filtering parameters, determining the timeliness of the results based on relevant parameters, and specifically analyzing and processing relevant situations.

Ketiga, the average interpolation calculation software is a software system with strong calculation functions, which can perform real-time calculation and verification of average interpolation, in order to improve the efficiency of calculation results and data comparison analysis in the future.

Fourthly, display the software structure of the output, and after all processes are completed, use the output software to complete data processing and output. Untuk terus melaksanakan pemantauan masa nyata keselamatan peralatan, adalah perlu untuk meningkatkan ketepatan masa proses pemantauan dengan menggabungkan parameter maklum balas.

Selain itu, dalam kerja pengumpulan maklumat, jabatan teknikal harus memberi tumpuan kepada hubungan antara struktur pengumpulan dan sistem aplikasi, meningkatkan kerasionalan proses pengumpulan dan proses komunikasi pada mesin dengan berkesan, dan menaik taraf proses pengumpulan untuk memastikan prestasi masa nyata dan integriti kesan aplikasi. Perkara yang paling penting ialah aplikasi sistem perisian harus mengambil penambahbaikan CPU sebagai prasyarat, dan berdasarkan kecekapan penggunaan bersepadu, menjalankan analisis berpusat dan pertimbangan terhadap kualiti operasi permulaan proses perisian, functional processing operation instructions, and timed interrupt function instructions, in order to reasonably improve control standards.

On the basis of comprehensive analysis and system optimization of point type fiber optic temperature sensors, the application process of sensors in power equipment monitoring has been tested in the structure of 10kV high-voltage switchgear, which can effectively form 9-point monitoring. On the basis of traditional technology, system calibration and experimental testing are carried out by directly placing the fiber optic sensor in the electric constant temperature box of the equipment, effectively meeting the temperature control efficiency. During the experiment, the temperature gradually increased from room temperature. The operator needs to measure the temperature and coefficient analog output of the constant temperature box at different temperature intervals, effectively integrate the temperature values, and improve the final processing effect. On the basis of the joint action of thermocouple thermometer and mercury temperature sensor, corresponding temperature parameters are obtained. After using thermocouple thermometers and mercury thermometers to detect temperature, it can be used as a reference value for the temperature of the constant temperature chamber.

In actual measurement work, in order to comprehensively understand the time stability of fiber optic temperature sensors during operation, attention should be paid to data feedback after continuous measurement, ensuring the selection of basic temperature control conditions, and based on this, obtaining differentiated measurement results of fiber optic temperature sensors formed by changes in time,

Time stability test curve of fiber optic thermometer

It is not difficult to find that temperature measurement is unstable in the context of continuous accumulation of time. Combining measurement information can determine the temperature drift effect of temperature sensors and explore the measurement accuracy of temperature sensors. It can be seen that the stability of time is of great significance for the quality of the monitoring process. Selain itu, sensors mainly use fiber optic technology, which is heat-resistant and can be directly placed in temperature control systems. By controlling the temperature between -20 kepada 125 ℃, the system can also operate normally.

Sensor suhu gentian optik untuk pengukuran suhu suis

Selepas menentukur dan menguji sistem pemasangan sistem, adalah perlu untuk memastikan tahap penggunaan suis sebenar. Proses pemasangan casis sistem juga perlu menganalisis bahagian voltan rendah suis, terutamanya ikatan ringan dan struktur paip yang menyambungkan casis dan probe. Untuk memastikan ketepatan masa kecekapan pemprosesan, adalah perlu untuk memastikan bahawa parameter lentur gentian memenuhi keperluan sebenar semasa proses pemasangan dan mengelakkan percampuran gentian yang menjejaskan penggunaan gentian. Biasanya, mengukur parameter data memerlukan mewujudkan hubungan sambungan melalui bas bersiri RS485 dan menyambungkannya di dalam bilik pemantauan. Combined with the accumulated data during software operation, temperature testing and analysis are carried out at different points to effectively improve the basic level of system alarm. In the process of sensor application, it is necessary to measure and analyze the temperature of high-voltage transmission cable joints. The number of monitoring measurements should be controlled at 20 atau lebih, and a monitoring network should be established using RS485 to analyze and transmit information to different fixed points in the system, forming a monitoring structure. It is precisely because the system can measure the temperature of the contacts of the cable system, and if the temperature is high, it will give an alarm, which can to some extent avoid accidents.

Using fiber optic sensors for systematic analysis and safety monitoring of electronic devices can effectively improve data analysis results, ensure the integrity of subsequent data analysis and judgment efficiency, and ensure the rationality of absorption rate on the basis of effectively integrating light intensity parameters, laying the foundation for comprehensive optimization of measurement accuracy.

siasatan

Sensor suhu gentian optik, Sistem pemantauan pintar, Pengeluar gentian optik yang diedarkan di China

Pengukuran suhu gentian optik pendarfluor Peranti pengukuran suhu gentian optik pendarfluor Sistem pengukuran suhu gentian optik pendarfluor teragih