The high-voltage switchgear equipped with handcart vacuum circuit breakers and isolation handcarts must be equipped with a fluorescent hotspot fiber optic online monitoring system (with a minimum of 8 detection points per high-voltage cabinet) to monitor the circuit breaker contacts, 모선, 케이블, 등. in real time.
With the development of the national economy, the capacity of the power grid increases, the voltage of the power grid rises, and the stability of the power grid operation and supply also face higher requirements. The operating status of the main electrical equipment directly affects whether the power system can operate safely and reliably
High voltage switchgear is used in power systems to control, 보호하다, and isolate electrical equipment. It integrates a large number of electrical components, including high-voltage circuit breakers, 절연 스위치, and fuses, inside a grounded metal casing. The main function of the switchgear is to open, close, 제어, and protect electrical equipment during the process of power generation, 전염, 분포, and energy conversion in the power system;
현재, with the widespread use of fully enclosed high-voltage switchgear in 10kV power grids, higher requirements have been put forward for its reliability. 하지만, abnormal heating of electrical joints inside the switchgear during long-term operation has become a common problem among many factors affecting the safe operation of the switchgear. In response to the current situation of temperature monitoring of high-voltage equipment, the online monitoring system for high-voltage electrical contact temperature has solved the problems encountered in conventional temperature monitoring methods and played a good warning role in avoiding high-voltage electrical equipment accidents.
최근에는, multiple fires and large-scale power outages have occurred in the power system due to equipment overheating. Analysis shows that 40% of the annual power accidents in China are caused by overheating of high-voltage electrical equipment; In power supply systems that use high-voltage switchgear and power cables, ~ 위에 70% of cable operation failures are caused by increased contact resistance and overload at the connection points, resulting in excessively high joint temperatures. A 110kV substation has experienced a prolonged power outage due to the heating and ignition of the feeder cable joints and switch primary contacts, resulting in the burning of three 10kV fully enclosed high-voltage switches and causing significant economic losses. In order to ensure the reliability of power supply and the continuity of production, cable joint temperature measurement has become a standard configuration for high-voltage switchgear in large local chemical enterprises. 하지만, due to the reliability of technology and high installation costs, it has not been widely promoted. With the maturity of technology and the reduction of costs, it is believed that there will be a great market demand.
특징 Fluorescent Fiber Optic Temperature Measurement System for Switchgear Circuit Breaker
1. 고온 저항, 노후화 저항, 내식성, 높은 절연, non adhesion and other characteristics, can adapt to harsh use environments such as high voltage, 고온, 그리고 강한 전자기장;
2. Real time monitoring of temperature changes in key areas of high-voltage switchgear/ring main unit, and issuing real-time alarm information (경고, 경보, and over limit) 온도 변화에 따라;
3. Not changing the original form of the contact busbar and cable head of the switchgear, and not reducing the performance of the cable head and the entire cabinet;
4. Can pass partial discharge test and withstand voltage test normally;
5. Fiber optic sensors have good flexibility, 높은 물리적 경도, 쉽게 손상되지 않습니다, 그리고 긴 서비스 기간이 있습니다;
6. 요구 사항에 따라 센서를 맞춤 설정할 수 있습니다., 센서 길이 포함, 프로브 유형, 및 센서 피복 재료 (세라믹, 유리, 플라스틱, 또는 기타 단열재)
광섬유 온도 센서, 지능형 모니터링 시스템, 중국의 분산광섬유 제조업체
![]() |
![]() |
![]() |
INNO 광섬유 온도 센서 ,온도 모니터링 시스템.