के निर्माता फाइबर ऑप्टिक तापमान सेंसर, तापमान निगरानी प्रणाली, पेशेवर OEM/ODM कारखाना, थोक विक्रेता, आपूर्तिकर्ता.अनुकूलित.

ई-मेल: web@fjinno.net |

ब्लॉग

पावर केबल फॉल्ट लोकेशन और मॉनिटरिंग डिवाइस के क्या फायदे हैं?

Power cable fault location monitoring device, ऊंचाई: ≤ 3000m.

परिवेश का तापमान

Maximum temperature:+45 ℃;

Minimum temperature: -25 ℃;

Maximum daily temperature difference: 25K.

Wire temperature

Maximum temperature:+100 ℃;

Minimum temperature: -40 ℃.

Solar radiation intensity: 0.1W/cm2 (wind speed 0.5m/s) (outdoors).

Seismic resistance capability

Seismic intensity: 8 डिग्री;

Ground horizontal acceleration: 0.25g;

Ground vertical acceleration: 0.125g;

The seismic wave is a sine wave with a duration of three cycles and a safety factor of 1.67.

नमी

5% को 100% आरएच.

atmospheric pressure

550hPa to 1060hPa.

Polluted conditions

Pollution level: Level E;

The installation site is located in an outdoor area within 1km of the coast, with a salt density greater than 0.25-0.35mg/cm2;

The shell materials, bolts, and protection levels of sensors, high-frequency cables, acquisition boxes, and terminal boxes should meet the requirements of corrosion resistance, and serious rusting should not occur during operation.

wind speed

मॉनिटरिंग डिवाइस को सामान्य रूप से ≤ 45m/s के झोंकों के तहत काम करना चाहिए.

safety requirements

कंप्यूटर कक्षों के लिए GB4943 में प्रासंगिक नियमों और GB9361 में क्लास बी सुरक्षा नियमों का अनुपालन करें.

कार्यशील विद्युत आपूर्ति

रेटेड वोल्टेज: एसी 220V 15%;

Frequency: 50हर्ट्ज;

हार्मोनिक सामग्री:<5%.

बर्फ की मोटाई

10मिमी (आउटडोर).

जब उपकरण हवा जैसे कठोर प्राकृतिक वातावरण में काम करता है, आंधी, ठंडा और मजबूत विद्युत चुम्बकीय वातावरण, इसकी कार्यशील स्थिरता और विश्वसनीयता पर कोई विशेष प्रभाव नहीं पड़ेगा.

मॉनिटरिंग डिवाइस के कनेक्शन से मॉनिटर किए गए केबल बॉडी की विद्युत कनेक्शन विधि में बदलाव नहीं होना चाहिए, और सीलिंग प्रदर्शन जैसे विभिन्न प्रदर्शन संकेतकों को प्रभावित नहीं करना चाहिए, इन्सुलेशन प्रदर्शन, और यांत्रिक प्रदर्शन.

सेंसर रेटेड ऑपरेटिंग वोल्टेज का सामना करने में सक्षम होना चाहिए, ओवरवोल्टेज का संचालन, और जीबी/टी में निर्दिष्ट आवेग ओवरवोल्टेज 7674.

सेंसर हाउसिंग को विश्वसनीय रूप से ग्राउंड किया जाना चाहिए, और सेंसर के आउटपुट टर्मिनल में वोल्टेज सीमित सुरक्षा फ़ंक्शन होना चाहिए. नो-लोड आउटपुट वोल्टेज से व्यक्तिगत सुरक्षा को खतरा नहीं होना चाहिए.

निगरानी उपकरणों की स्थापना को निम्नलिखित आवश्यकताओं को पूरा करना चाहिए: आस-पास के हाई-वोल्टेज लाइव भागों और क्षेत्रों से पर्याप्त सुरक्षा दूरी; आकाशीय बिजली से प्रभावी सुरक्षा, स्विच ऑपरेशन के कारण ओवरवॉल्टेज और ग्राउंड संभावित वृद्धि; बिजली आपूर्ति से संबंधित कोई सुरक्षा खतरा नहीं, विद्युत चुम्बकीय संगतता, और नेटवर्क संचार, और अन्य प्रणालियों के सुरक्षित संचालन पर कोई प्रभाव नहीं पड़ेगा.

निगरानी उपकरणों के लिए बुनियादी आवश्यकताएँ

डिवाइस को मॉड्यूलरिटी और मानकीकरण की आवश्यकताओं को पूरा करना चाहिए, और डेटा अधिग्रहण इकाइयों और सेंसर के विस्तार को सुविधाजनक बनाने के लिए पर्याप्त चैनल आरक्षित करें, supporting hot plugging and interchangeability requirements.

The on-site signal acquisition control unit and monitoring host should use reliable dedicated power supply.

The device should have an on-site verification and testing interface to facilitate users in conducting on-site debugging and testing.

The device should have overcurrent and lightning protection functions.

The device box should have anti-theft lock function, and the anti-theft lock should use passive electromagnetic lock.

The monitoring range of the device is from above the outdoor cable terminal to below the GIS terminal.

Basic requirements for monitoring system software

मॉनिटरिंग डिवाइस का सहायक सॉफ़्टवेयर खराबी और दोष के समय दोष बिंदु और पावर केबल के दोनों सिरों के बीच क्षणिक यात्रा तरंगों के प्रसार समय को एकत्र करता है।, और दोष बिंदु और केबल के दोनों छोर के बीच की दूरी की ऑनलाइन गणना करता है. फ्रंट-एंड डेटा प्रोसेसिंग डिवाइस सिग्नल प्राप्त करता है और इसे डेटा रिसीवर तक पहुंचाता है. डेटा रिसीवर से होकर होस्ट तक पहुंचने के बाद, बैक-एंड होस्ट डेटा प्राप्त करता है और अंततः दोष बिंदु का स्थान निर्धारित करने के लिए तरंग रूप निदान और विश्लेषण करता है. स्थिति निर्धारण त्रुटि L है * 0.5%+5एम (एल केबल की लंबाई है).

पावर केबल दोषों की सटीक स्थिति के लिए केवल केबल के प्रत्येक छोर पर निगरानी टर्मिनलों का एक सेट स्थापित करने की आवश्यकता होती है; यदि केबल में टी-जंक्शन है, a set should be installed on each section of the cable’s T-junction to achieve precise positioning in case of cable T-junction faults. The on-site monitoring terminal is fixedly installed near the grounding box of the cable terminal cover, and the sensor is mounted on the cable body and grounding wire. Each set of precise fault location device for power cables includes a monitoring terminal and one set of sensors for each of phases A, B, and C; Each set of sensors includes a traveling wave sensor and a power frequency current sensor. The monitoring terminal includes core units such as power module, communication module, time synchronization module, and data processing module.

The data transmission adopts wireless/wired methods. If wireless transmission is used, the monitoring data is processed by the front-end data processing unit using a wireless APN private network (including 4G/5G, वगैरह।), which meets the requirements of Q/CSG1205031-2020Transmission Line Online Monitoring Communication Protocol and Information Interaction Specification (Trial)”. The winning bidder shall assist in the implementation of the monitoring data access cable online monitoring platform for the bidding products, including data access development, system software system release, and on-site services.

The software can automatically perform online monitoring and diagnostic analysis on the fault waveforms of cable line tripping collected by on-site monitoring terminals. The backend software collects monitoring data in real-time for a long time and establishes historical data files, and plots these data into various curves. Cable operation and maintenance personnel can understand the long-term operation status of the entire cable based on the information provided by these curves. एक ही समय पर, the software processes the collected current data and provides device status alarms, cable current abnormality alarms, and cable fault alarms. And promptly notify the operation and maintenance management personnel of the diagnosis results through web terminals or SMS. Enable line operation and maintenance personnel to constantly monitor the operation status of cables, promptly warn of cable faults, and quickly locate the fault point after the fault occurs.

Functional requirements for monitoring system software

Cable fault interval positioning

For hybrid overhead cable lines, it is possible to determine whether the fault is located in the cable section or the overhead section.

Accurate positioning of cable faults

After a cable fault occurs, it can quickly and accurately locate the location of the cable fault point.

Dual end traveling wave fault location function

Realize automatic dual end positioning; Realize manual input of dual end start time positioning; The initial arrival time of the fault wavefront can be manually corrected.

संचार समारोह

Support wireless APN/wired communication methods, capable of receiving defect and fault transient traveling wave data from the station end traveling wave acquisition device; Can manually and automatically retrieve station data; Communication parameters can be configured.

Data management function

Implement configuration data management; गलती रिकॉर्ड डेटा प्रबंधन लागू करें; डेटा आयात और निर्यात: आप कॉन्फ़िगरेशन या फ़ॉल्ट रिकॉर्ड को अलग से आयात और निर्यात कर सकते हैं.

निगरानी उपकरणों के लिए कार्यात्मक आवश्यकताएँ

आंकड़ा अधिग्रहण

मॉनिटरिंग टर्मिनल स्वचालित रूप से निगरानी कर सकता है, इकट्ठा करना, और वेवफॉर्म डेटा को स्टोर करें जैसे कि केबल की फॉल्ट ट्रिपिंग ट्रैवलिंग वेव करंट;

घड़ी तुल्यकालन

साइट पर निगरानी टर्मिनलों को केबल के दोनों सिरों पर यात्रा तरंग अधिग्रहण उपकरणों के बीच सटीक घड़ी सिंक्रनाइज़ेशन बनाए रखने के लिए विश्वसनीय तरीकों का उपयोग करना चाहिए, और सुनिश्चित करें कि दोनों डिवाइसों की क्लॉक त्रुटि अधिक न हो 20 गलती के समय पल्स तरंग के नमूने के समय एनएस.

डेटा संचार

मॉनिटरिंग टर्मिनल वास्तविक समय डेटा भेज सकता है (जैसे दोष यात्रा तरंगें) and device heartbeat information collected in accordance with the message format specified in Q/CSG1205031-2020Transmission Line Online Monitoring Communication Protocol and Information Interaction Specification (Trial)”, and send them to the backend system center station through APN private network wireless/wired network communication; The monitoring terminal can automatically save the collected monitoring data in case of communication interruption, and promptly transmit the stored data back to the central station after the terminal communication is restored; Cable fault traveling wave messages have priority for transmission.

Equipment self check and self recovery function

The device should have a self detection function, providing timed self check information on the device’s operating status, recording fault logs, and the detection cycle can be set. The device should have a self recovery function. In the event of abnormal power supply termination or other situations, the device should be able to automatically resume normal operation without losing stored data.

Anti interference function

It should have the ability to effectively suppress and eliminate background interference in complex electromagnetic environments on site, and anti-interference technologies such as filtering, shielding, identification, and positioning can be used to ensure the effectiveness of monitoring.

Structure and appearance

The installation of online monitoring devices should pay attention to safety and aesthetics, and wiring should have cable trays or protective sheaths; The installation of sensors does not affect the daily testing and maintenance of cables; The terminal box should be tailored to local conditions, और सबस्टेशन में केबल बिछाने के स्थान को सबस्टेशन संचालन इकाई द्वारा अनुमोदित किया जाना आवश्यक है.

स्थानीय सिग्नल उपकरणों को लाइव परीक्षण के लिए इंटरफेस आरक्षित करना चाहिए.

मॉनिटरिंग यूनिट को स्टेनलेस स्टील चेसिस द्वारा संरक्षित किया जाना चाहिए, जिसे लचीले ढंग से खोला जा सकता है और कसकर मिलान किया जा सकता है. चेसिस के अंदर कोई धूल या मलबा नहीं होना चाहिए. चेसिस के आंतरिक भाग को नमी प्रतिरोध की आवश्यकता होती है.

चेसिस को विद्युत चुम्बकीय हस्तक्षेप को रोकने के लिए आवश्यक उपाय करने चाहिए, और चेसिस के खुले प्रवाहकीय हिस्से विद्युत रूप से जुड़े होने चाहिए और विश्वसनीय रूप से ग्राउंडेड होने चाहिए.

चेसिस की सतह को यांत्रिक क्षति नहीं होनी चाहिए, scratches, दरारें, या विरूपण. बाहरी कोटिंग और इलेक्ट्रोप्लेटिंग परत दृढ़ होनी चाहिए, वर्दी, और चिकना, बिना छीले या जंग लगे. चेसिस किसकी बनी होनी चाहिए 304 stainless steel material.

The bottom plates, baffles, and components inside the cabinet should be firmly fixed without burrs, the bolts should be flat, and the control components such as keyboards and buttons should be flexible. The display and markings on the panel should be clear.

The electrical and communication cable lines are firmly connected, with a reasonable and beautiful direction. Each connecting sleeve is labeled, and the exposed parts of each welding point are covered with heat shrink tubing. The power supply incoming line is labeled with a strong current sign.

Both the exterior and interior of the device should be designed with flame retardant, विस्फोट विरोधी, विरोधी जंग, moisture-proof, वगैरह. The hardware of the device should use industrial grade or above components.

पावर और सिग्नल सॉकेट में वाटरप्रूफ एविएशन प्लग का उपयोग होना चाहिए और इसमें गलत संचालन रोधी डिज़ाइन होना चाहिए; डिवाइस में एक संरचनात्मक डिज़ाइन होना चाहिए जिसे उठाना और परिवहन करना आसान हो.

Power supply method

केबल दोषों के लिए सटीक पोजिशनिंग डिवाइस मुख्य बिजली आपूर्ति विधि के रूप में सीटी इंडक्शन पावर सप्लाई/मेन पावर/स्टेशन पावर सप्लाई को अपनाता है।, और सौर ऊर्जा आपूर्ति का उपयोग सहायक बिजली आपूर्ति विधि के रूप में किया जा सकता है.

जाँच करना

फाइबर ऑप्टिक तापमान सेंसर, बुद्धिमान निगरानी प्रणाली, चीन में वितरित फाइबर ऑप्टिक निर्माता

फ्लोरोसेंट फाइबर ऑप्टिक तापमान माप फ्लोरोसेंट फाइबर ऑप्टिक तापमान माप उपकरण वितरित प्रतिदीप्ति फाइबर ऑप्टिक तापमान माप प्रणाली

पिछला:

अगला:

एक संदेश छोड़ें