- Thermal failures account for 55-60% के सभी IGBT module विफलताएं, निर्माण तापमान की निगरानी absolutely critical
- For every 10°C rise above rated junction temperature, IGBT lifespan is reduced by half
- परंपरागत तापमान सेंसर suffer fatal flaws in high-voltage, high-EMI बिजली के इलेक्ट्रॉनिक्स environments
- फ्लोरोसेंट फाइबर ऑप्टिक तापमान सेंसर provide complete electrical isolation and immunity to electromagnetic interference
- One fiber optic cable measures one specific hotspot; single transmitters support 1-64 स्वतंत्र चैनल
- Properly implemented multi-point थर्मल निगरानी extends IGBT service life द्वारा 20-40%
विषयसूची
- What is an IGBT Module?
- How Do IGBT Power Modules Work?
- What Are the Main IGBT Applications?
- Why Is IGBT Thermal Management Critical?
- What Are Common IGBT Failure Modes?
- Why Do IGBT Temperature Abnormalities Occur?
- What IGBT Temperature Monitoring Technologies Exist?
- Why Choose Fiber Optic Sensors for IGBT Monitoring?
- How Is an IGBT Temperature Monitoring System Configured?
- How to Implement IGBT Temperature Monitoring?
- How Are Temperature Monitoring Data Applied?
- IGBT Monitoring Application Case Studies
- अक्सर पूछे जाने वाले प्रश्नों
- Get Your Custom IGBT Monitoring Solution
1. What is an IGBT Module?
एक आईजीबीटी (विद्युत रोधित गेट द्विध्रुवी ट्रांजिस्टर) is a three-terminal power semiconductor device combining the high input impedance characteristics of MOSFETs with the low on-state voltage drop of bipolar transistors. IGBT modules package one or more IGBT chips together with anti-parallel freewheeling diodes, gate drivers, and thermal interfaces into a single assembly designed for high-power switching applications.
आधुनिक IGBT power modules form the core switching elements in motor drives, इन्वर्टर, और power converters ranging from kilowatts to megawatts. एक ठेठ IGBT module consists of silicon chips mounted on Direct Bonded Copper (DBC) ceramic substrates, wire-bonded connections, silicone gel encapsulation, and a baseplate for thermal management—all integrated into a rugged housing with standardized mounting and electrical interfaces.
IGBT Module Core Components
- IGBT chips – Silicon dies providing controlled switching function
- Freewheeling diodes – Anti-parallel diodes handling reverse current
- DBC substrate – Ceramic substrate with copper layers for electrical connection and heat spreading
- Wire bonds – Aluminum or copper wires connecting chips to terminals
- Baseplate – Metal plate (typically copper or aluminum) interfacing to heatsink
- Terminals – Power and control connections
2. How Do IGBT Power Modules Work?
IGBT operation involves voltage-controlled switching between on-state (conducting) and off-state (blocking). When a positive voltage (typically 15V) is applied to the gate terminal relative to the emitter, an inversion layer forms in the MOSFET channel, allowing current flow from collector to emitter. Removing the gate voltage turns off the device, blocking current flow.
Power Loss Mechanisms in IGBTs
IGBT power dissipation occurs through two primary mechanisms that generate heat requiring thermal management:
Conduction Losses
During the on-state, current flowing through the आईजीबीटी encounters resistance, dissipating power according to P = V_CE(sat) × I_C. Conduction losses increase linearly with load current and are influenced by junction temperature—higher temperatures increase on-state voltage drop.
Switching Losses
During turn-on and turn-off transitions, the आईजीबीटी simultaneously experiences high voltage and high current, generating substantial power dissipation. Switching losses increase with switching frequency, making high-frequency applications particularly thermally demanding. कुल switching loss per cycle equals the integral of instantaneous voltage × current during transitions.
In a typical motor drive inverter पर संचालन 10 kHz switching frequency with 200A load current, a single IGBT module may dissipate 200-400 watts continuously, generating significant heat that must be removed to prevent junction temperature from exceeding rated limits (typically 125-175°C depending on device rating).
3. What Are the Main IGBT Applications?
IGBT modules enable efficient power conversion and motor control across diverse industrial and transportation applications:
Electric Vehicle Powertrains
EV inverters उपयोग IGBT modules (increasingly being replaced by SiC in newer designs) to convert DC battery voltage to three-phase AC for traction motors. एक ठेठ 100 किलोवाट EV inverter contains 6 IGBT modules in a three-phase bridge configuration, switching at 10-20 kHz. DC fast chargers employ IGBT-based power factor correction and DC-DC conversion stages handling 50-350 किलोवाट.
रेल परिवहन
Traction inverters for high-speed trains and metro systems use large IGBT modules (1700वी, 3300वी, or 6500V class) managing multi-megawatt power levels. A single train may contain 50-100+ IGBT modules across multiple inverter units.
Industrial Motor Drives
परिवर्तनीय आवृत्ति ड्राइव (VFDs) for pumps, प्रशंसक, compressors, and manufacturing equipment rely on IGBT-based inverters from 1 kW to several megawatts. Servo drives for precision motion control use आईजीबीटी for dynamic torque regulation.
नवीकरणीय ऊर्जा प्रणालियाँ
Wind turbine converters काम IGBT modules in generator-side and grid-side converters managing 2-15 MW per turbine. Solar inverters उपयोग आईजीबीटी for DC-AC conversion from 1 kW residential systems to 1 MW+ utility-scale installations.
Power Grid Infrastructure
HVDC transmission systems और FACTS devices (Static VAR Compensators, STATCOMs) use high-voltage IGBT modules for efficient long-distance power transmission and reactive power compensation.
Other Applications
Induction heating, welding equipment, UPS systems, और energy storage converters all utilize IGBT technology for efficient power control and conversion.
4. Why Is IGBT Thermal Management Critical?
असरदार थर्मल प्रबंधन represents the most critical factor determining IGBT reliability and lifespan. The relationship between junction temperature and device degradation is exponential—small temperature increases dramatically accelerate failure mechanisms.
Junction Temperature and Lifespan Relationship
The Arrhenius equation governs thermally-activated degradation processes in semiconductor devices. के लिए IGBT modules, empirical data shows that every 10°C increase above rated junction temperature reduces expected lifespan by approximately 50%. An IGBT operating at 125°C junction temperature might achieve 100,000 hours service life, but the same device at 145°C would fail after only 25,000 घंटे.
Thermal Cycling Fatigue
Temperature cycling—repeated heating and cooling during operation—creates mechanical stress from coefficient of thermal expansion (CTE) mismatches between different materials in the IGBT module assembly. Silicon chips, copper conductors, ceramic substrates, and solder layers all expand and contract at different rates, generating fatigue that eventually causes bond wire liftoff, solder delamination, or chip cracking.
Thermal Runaway Risk
जैसा IGBT junction temperature increases, on-state voltage drop rises, increasing conduction losses and generating additional heat. Without adequate cooling, this positive feedback loop can lead to thermal runaway and catastrophic failure within seconds.
5. What Are Common IGBT Failure Modes?
Field failure analysis of IGBT modules across various applications reveals consistent failure mode distributions:
Thermal-Related Failures (55-60% of all failures)
- Solder layer fatigue and delamination – Thermal cycling causes solder joints between chips, DBC, and baseplate to crack and separate, increasing thermal resistance
- Bond wire liftoff – Aluminum or copper wire bonds detach from chip surface due to CTE mismatch and thermal cycling, causing open circuits or current redistribution increasing stress on remaining wires
- Chip cracking – Extreme thermal stress or rapid temperature transients crack silicon dies
- Encapsulation degradation – Silicone gel ages and degrades at elevated temperatures, losing dielectric strength
Electrical Failures (25-30%)
- Gate oxide breakdown – Overvoltage or sustained high temperature degrades gate insulation
- Latch-up – Parasitic thyristor activation causing loss of control
- Short circuit damage – Overcurrent events exceeding safe operating area
Mechanical Failures (10-15%)
- Thermal stress-induced mechanical damage – Warping, delamination from thermal expansion
- Vibration and shock damage – Particularly in transportation applications
6. Why Do IGBT Temperature Abnormalities Occur?

IGBT overheating results from various operational, environmental, and system design factors:
- अधिभार संचालन – Current exceeding rated values increases both conduction and switching losses beyond cooling capacity
- Cooling system failure – Water pump malfunction, coolant leaks, heat exchanger fouling, or fan failure reduce heat removal
- Elevated ambient temperature – High environmental temperatures reduce thermal margin and cooling effectiveness
- Inadequate heatsink design – Insufficient surface area or poor thermal interface contact
- Thermal interface material degradation – Thermal grease or pads dry out, increasing thermal resistance
- Current imbalance in parallel modules – Unequal current sharing causes individual modules to overheat while others remain cooler
- Improper control parameters – Excessive switching frequency or dead time settings increasing losses
7. What IGBT Temperature Monitoring Technologies Exist?
विभिन्न temperature sensing technologies offer different capabilities for IGBT thermal monitoring:
| तकनीकी | विद्युत अलगाव | ईएमआई प्रतिरक्षा | शुद्धता | Temp Range | IGBT Suitability |
|---|---|---|---|---|---|
| फ्लोरोसेंट फाइबर ऑप्टिक सेंसर | पूरा (>10के.वी) | प्रतिरक्षा | ±1°C | -40 to +260°C | उत्कृष्ट |
| NTC Thermistors | Requires isolation circuit | गरीब | ±1-2°C | -50 से +150°C तक | सीमित |
| थर्मोकपल्स | Requires isolation amplifier | गरीब | ±1-2°C | -200 to +1200°C | सीमित |
| Infrared Thermometry | पूरा (गैर-संपर्क) | प्रभावित नहीं | ±2-5°C | -20 to +1500°C | Surface only |
| एंबेडेड सेंसर | Integrated design | भिन्न | ±2-5°C | -40 to +175°C | Limited availability |
Traditional Sensor Limitations in IGBT Applications
NTC thermistors और थर्मोकपल्स contain metallic components susceptible to electromagnetic interference from the high-frequency switching (5-20 kHz typical) and high dV/dt transients in power electronic converters. These sensors require complex isolation circuits and filtering, adding cost and reducing reliability. The kilovolt-level common-mode voltages between power and control grounds in IGBT drives make direct electrical connection of conventional sensors extremely challenging.
8. Why Choose Fiber Optic Sensors for IGBT Monitoring?
फ्लोरोसेंट फाइबर ऑप्टिक तापमान सेंसर uniquely address the severe challenges of IGBT temperature measurement in high-voltage, high-EMI बिजली के इलेक्ट्रॉनिक्स environments.
How Fluorescent Fiber Optic Sensors Work
A miniature probe tip (1-3मिमी व्यास) contains rare-earth phosphor material that fluoresces when excited by blue LED light transmitted through an optical fiber. The fluorescent decay time varies predictably with temperature from microseconds to milliseconds. The फाइबर ऑप्टिक तापमान ट्रांसमीटर measures this decay time and converts it to calibrated temperature with ±1°C accuracy, completely independent of light intensity, फाइबर झुकना, या कनेक्टर हानि.
Core Advantages for IGBT Monitoring
पूर्ण विद्युत अलगाव
The dielectric प्रकाशित तंतु provides inherent electrical isolation exceeding 10 kV between the measured IGBT module and the monitoring instrumentation. This eliminates ground loop formation, common-mode voltage issues, and safety hazards when monitoring high-voltage power modules.
विद्युतचुम्बकीय हस्तक्षेप के प्रति प्रतिरक्षण
Optical signal transmission is completely immune to electromagnetic fields. फाइबर ऑप्टिक सेंसर operate reliably in the extreme EMI environment surrounding आईजीबीटी—high dV/dt switching transients, strong magnetic fields from bus bars and inductors, and radiofrequency emissions—without requiring shielding or filtering.
Compact Size and Flexible Installation
The 1-3mm diameter probe and flexible optical fiber cable enable installation in confined spaces within IGBT modules and power assemblies. Sensors can be positioned directly on chip surfaces, DBC substrates, or thermal interfaces where conventional sensors cannot fit.
Wide Temperature Range and High Accuracy
Standard sensors measure -40°C to +260°C with ±1°C accuracy, covering the full range from ambient to maximum rated junction temperatures of IGBT devices. त्वरित प्रतिक्रिया समय (<1 दूसरा) captures rapid thermal transients.
Multi-Channel Architecture
One fiber optic cable measures one specific hotspot location. Fiber optic temperature transmitters सहायता 1-64 स्वतंत्र चैनल, each connecting to a dedicated sensor via individual optical fiber. This enables comprehensive multi-point monitoring with a single instrument.
लंबी दूरी का ट्रांसमिशन
प्रत्येक प्रकाशित तंतु transmits signals up to 80 meters without degradation, allowing centralized transmitter installation in control rooms while monitoring remote power modules in harsh industrial environments.
9. How Is an IGBT Temperature Monitoring System Configured?
एक पूर्ण IGBT thermal monitoring system integrates sensors, आंकड़ा अधिग्रहण, संचार, and software layers.
Critical Temperature Monitoring Points
असरदार IGBT monitoring requires measuring temperatures at multiple strategic locations:
- IGBT chip surface temperature – 2-3 sensors per module positioned at known hotspots
- Freewheeling diode temperature – 1-2 सेंसर (diodes often run hotter than IGBTs)
- DBC substrate temperature – 1 sensor measuring intermediate thermal resistance
- Baseplate temperature – 1 sensor assessing heat transfer to heatsink
- Heatsink or coolant temperature – 1-2 sensors verifying cooling system performance
Typical single IGBT module configuration: 4-8 फाइबर ऑप्टिक सेंसर
System Architecture Components
Sensor Layer
फ्लोरोसेंट फाइबर ऑप्टिक तापमान जांच installed at critical monitoring points using thermal adhesive or mechanical mounting. Each sensor connects via individual optical fiber cable to the transmitter.
Data Acquisition Layer
Fiber optic temperature transmitters (available in 1, 4, 8, 16, 32, and 64-channel configurations) convert optical signals to calibrated temperature readings. Each channel measures one dedicated sensor location.
Communication Layer
Industry-standard interfaces including मोडबस आरटीयू/टीसीपी, ईथरनेट/आईपी, PROFINET, analog outputs (4-20एमए), और relay contacts for alarm annunciation enable integration with PLCs, स्काडा सिस्टम, and motor drive controllers.
Application Layer
Monitoring software provides real-time displays, ट्रेंडिंग, अलार्म प्रबंधन, डेटा प्रविष्ट कराना, and predictive analytics for maintenance optimization.
10. How to Implement IGBT Temperature Monitoring?
सफल IGBT monitoring system implementation follows a structured approach:
कदम 1: System Planning
- Identify critical IGBT modules requiring monitoring based on power rating, तापीय तनाव, and failure history
- Determine sensor quantity: 4-8 sensors per module for comprehensive monitoring, या 2-3 sensors for cost-effective coverage
- चुनना fiber optic transmitter with adequate channel count (typical systems use 32 or 64-channel units)
कदम 2: सेंसर स्थापना
- Surface preparation – Clean mounting locations with isopropyl alcohol to remove oils and contaminants
- सेंसर संलग्नक – Apply high-temperature thermal adhesive (मूल्यांकन >200डिग्री सेल्सियस) to probe tip and press firmly onto IGBT chip, DBC substrate, or baseplate surface
- फाइबर रूटिंग – मार्ग ऑप्टिकल फाइबर केबल through cable trays or conduits to transmitter location, maintaining minimum bend radius (typically 25mm)
- फाइबर सुरक्षा – Use protective sleeving in areas subject to abrasion or sharp edges
कदम 3: सिस्टम एकीकरण
- Connect each प्रकाशित तंतु to designated transmitter channel, labeling clearly
- Configure transmitter parameters (temperature units, अलार्म दहलीज, communication settings)
- Connect communication interface to PLC, drive controller, or SCADA system
- Install monitoring software and configure data logging
कदम 4: Commissioning and Validation
- Verify all channels report plausible temperatures at ambient conditions
- Operate equipment at various load levels to establish baseline temperature profiles
- Set warning alarms 10-15°C below critical thresholds (typically 100-110°C for 125°C rated devices)
- Set critical alarms at manufacturer-specified maximum temperatures (typically 120-125°C)
- Document sensor locations, channel assignments, and alarm setpoints
11. How Are Temperature Monitoring Data Applied?
![]()
IGBT temperature data enables multiple operational and maintenance improvements:
Real-Time Monitoring and Protection
- Continuous display of all sensor temperatures with color-coded status (normal/warning/critical)
- Trend charts showing temperature evolution during load cycles
- Immediate alarm notification when thresholds exceeded, triggering load reduction or equipment shutdown
- Multi-point comparison identifying individual module overheating in parallel configurations
दोष निदान
- शीतलन प्रणाली की विफलता – All modules show elevated temperatures simultaneously
- Current imbalance – Individual module runs significantly hotter than paralleled units
- Thermal interface degradation – Increasing temperature differential between chip and heatsink over time
- Blocked coolant passages – High chip temperature with normal coolant temperature
पूर्वानुमानित रखरखाव
- प्रवृत्ति विश्लेषण – Gradually increasing temperatures over weeks/months indicate cooling degradation requiring maintenance
- शेष जीवन अनुमान – Accumulated thermal cycling and peak temperature exposure predict component wear-out
- Maintenance optimization – Schedule servicing based on actual thermal condition rather than arbitrary time intervals
Performance Optimization
- Load capacity assessment – Verify thermal margin available for increased production throughput
- Switching frequency optimization – Balance performance versus thermal stress
- Cooling system optimization – Adjust fan speed or coolant flow based on actual thermal load
12. IGBT Monitoring Application Case Studies
केस स्टडी 1: Electric Vehicle Inverter Thermal Protection
आवेदन: 100 kW traction inverter with 6 IGBT modules
संकट: Frequent thermal protection trips during highway acceleration
समाधान: 18-बिंदु फाइबर ऑप्टिक तापमान की निगरानी (3 sensors per module)
Finding: Coolant flow rate 30% below specification due to partially blocked heat exchanger
नतीजा: After cleaning heat exchanger, chip temperatures reduced from 115°C to 85°C, eliminating trips and extending expected module life by 40%
केस स्टडी 2: Wind Turbine Converter Reliability Improvement
आवेदन: 3 MW wind turbine power converters
विन्यास: 4 फाइबर ऑप्टिक सेंसर per critical IGBT module (16 modules monitored per turbine)
कार्यान्वयन: Remote monitoring via मोडबस टीसीपी to wind farm SCADA
परिणाम: Early detection of cooling fan failures and thermal interface degradation reduced unplanned downtime by 60%, enabling condition-based maintenance scheduling during low-wind periods
केस स्टडी 3: Metro Traction System Availability Enhancement
चुनौती: Summer heat waves causing train thermal shutdowns during peak commute hours
समाधान: विस्तृत IGBT temperature monitoring with predictive load derating algorithm
कार्यान्वयन: रियल टाइम junction temperature measurement integrated with traction control system
नतीजा: System availability improved from 97% को 99.5%; thermal shutdowns eliminated through intelligent thermal management maintaining temperatures below critical limits
13. Frequently Asked Questions About IGBT Temperature Monitoring
Q1: What is the difference between junction temperature and case temperature in IGBT modules?
ए: जंक्शन तापमान (T_j) is the actual temperature of the silicon chip where heat is generated. Case temperature (T_c) is measured on the module’s external surface (typically baseplate). The difference between them represents the thermal resistance of internal materials (solder, DBC, thermal grease). Junction temperature is the critical parameter for reliability, but direct measurement requires sensors inside the module. फाइबर ऑप्टिक सेंसर can be positioned on chip surfaces during manufacturing or on DBC substrates for close approximation of junction temperature.
Q2: Why do IGBT modules require multi-point temperature monitoring rather than single-point measurement?
ए: Temperature distribution within IGBT modules is non-uniform. Different chips (IGBT versus diode), different locations on the same chip, and different modules in parallel configurations all experience varying thermal stress. Single-point measurement may miss the hottest location. Multi-point monitoring identifies individual chip failures, current imbalances, and localized cooling problems that single sensors cannot detect.
Q3: How do fluorescent fiber optic sensors achieve electrical isolation in high-voltage IGBT applications?
ए: प्रकाशित तंतु is constructed from pure silica glass or plastic—completely non-conductive dielectric materials. Temperature information travels as light pulses, not electrical signals. There is no electrical path whatsoever between the sensor probe (in contact with high-voltage IGBT components) and the transmitter electronics (at ground potential). This provides inherent isolation exceeding 10 kV without requiring isolation transformers, optocouplers, or other components that can degrade or fail.
Q4: How many temperature sensors are typically needed per IGBT module?
ए: व्यापक निगरानी के लिए: 4-8 sensors per module (2-3 on IGBT chips, 1-2 on diode chips, 1 on DBC substrate, 1 on baseplate). For cost-effective coverage: 2-3 sensors per module focused on known hotspots. Multi-module systems often monitor every module individually for critical applications, or monitor representative modules supplemented by thermal modeling for others.
Q5: Can IGBT temperature monitoring integrate with existing motor drive or converter control systems?
ए: हाँ. Fiber optic temperature transmitters provide industry-standard communication protocols (मोडबस आरटीयू/टीसीपी, ईथरनेट/आईपी, PROFINET, analog 4-20mA outputs, relay contacts) compatible with virtually all PLCs and drive controllers. Temperature data can trigger protective actions (load derating, controlled shutdown), enable thermal modeling for real-time junction temperature estimation, or feed into predictive maintenance algorithms.
Q6: Where should temperature sensors be installed on IGBT modules for maximum effectiveness?
ए: Optimal locations: (1) IGBT chip centers where maximum power dissipation occurs, (2) Diode chip centers (often hottest due to reverse recovery losses), (3) DBC substrate between chips for average chip temperature, (4) Baseplate near chip locations for heat transfer assessment, (5) Heatsink or coolant for cooling system performance. Manufacturer thermal models or infrared surveys during operation identify specific hotspots for sensor placement.
क्यू 7: How should temperature alarm thresholds be set for IGBT protection?
ए: Set multi-level alarms: (1) Information level: 70-80डिग्री सेल्सियस – logged for trend analysis, (2) Warning level: 90-100डिग्री सेल्सियस – notify operators, निगरानी आवृत्ति बढ़ाएँ, (3) High alarm: 110-120डिग्री सेल्सियस – reduce load, activate enhanced cooling, (4) Critical alarm: 125-130डिग्री सेल्सियस – initiate controlled shutdown before reaching absolute maximum rating (typically 150-175°C). Exact thresholds depend on IGBT manufacturer specifications and application requirements.
Q8: What is the typical lifespan of fiber optic temperature sensors in IGBT applications?
ए: फ्लोरोसेंट फाइबर ऑप्टिक सेंसर exhibit exceptional longevity—20+ years of continuous operation with no calibration drift. The optical measurement principle has no consumable elements, moving parts, or degrading electronic components. Factory calibration remains accurate throughout the sensor’s life. This matches or exceeds the service life of the IGBT equipment being monitored, eliminating sensor replacement as a maintenance item.
प्रश्न 9: How many sensors can one fiber optic transmitter support?
ए: Fiber optic temperature transmitters are available in 1, 4, 8, 16, 32, and 64-channel configurations. Each channel connects to one dedicated sensor via one individual optical fiber cable, measuring one specific temperature point. A 32-channel transmitter can monitor 4-8 complete IGBT modules (पर 4-8 sensors per module), or provide comprehensive coverage for a complete power converter system including modules, heatsinks, and cooling system.
Q10: Can the same monitoring solution be used for Silicon Carbide (SiC) power modules?
ए: हाँ. SiC power modules operate at higher junction temperatures (up to 200°C versus 150°C for silicon IGBTs) and higher switching frequencies, making thermal monitoring even more critical. The -40°C to +260°C range of standard फाइबर ऑप्टिक सेंसर accommodates SiC temperature requirements. The high-frequency immunity is essential for SiC converters switching at 50-100+ kHz. The same sensor installation techniques and system architecture apply to both IGBT and SiC modules.
Get Your Custom IGBT Temperature Monitoring Solution
Contact Us to Receive:
- स्वनिर्धारित temperature monitoring system design for your specific IGBT application
- Detailed technical specifications and फाइबर ऑप्टिक सेंसर datasheets
- Sensor placement recommendations and installation drawings
- Complete system configuration and detailed quotation
- On-site installation support and commissioning services
Professional Services Include:
- Free application consultation and thermal analysis
- IGBT module sensor layout design
- Monitoring system integration with existing controls
- Factory acceptance testing and calibration verification
- Comprehensive training and long-term technical support
Protect your valuable IGBT assets with proven fiber optic temperature monitoring technology. Contact our power electronics monitoring specialists today for a solution tailored to your application.
फाइबर ऑप्टिक तापमान सेंसर, बुद्धिमान निगरानी प्रणाली, चीन में वितरित फाइबर ऑप्टिक निर्माता
![]() |
![]() |
![]() |
INNO फाइबर ऑप्टिक तापमान सेंसर ,तापमान निगरानी प्रणाली.