Transformer fiber optic temperature controller, real-time monitoring of transformer winding and iron core temperature, mainly composed of fiber optic temperature sensor and temperature controller.
(1) Plage de mesure de la température: 0~+200 ℃; Précision de la mesure de la température: ± 1 ℃; The fluorescent fiber optic sensor passes the power frequency withstand voltage test, with a 20cm withstand voltage of not less than 80kV, and provides an inspection report; The lifespan of fluorescent fiber optic sensors shall not be less than 30 années.
(2) The fiber optic temperature sensor is sealed with a set of high insulation material and directly contacts for measurement. It is seamlessly connected to the transmission fiber and only exchanges heat with the outside world.
(3) Le contrôleur de température receives temperature signals from fiber optic sensors and can achieve automatic, manuel, and remote start stop of the fan; Démarrer le ventilateur lorsque la température dépasse l'alarme de ligne; Déclenchement de la sortie du relais de surchauffe; Affichage numérique de la température; Télécharger le protocole de communication RS485 sur la télécommande.
(4) Le transformateur capteur de température à fibre optique est installé sur chaque côté d'enroulement de phase et sur le noyau de fer de chaque transformateur, connecté au contrôleur de température via des câbles à fibres optiques, et adopte une technologie réglable à plusieurs niveaux. Mesurer la température de l'enroulement triphasé et du noyau de fer en quatre points, et placez le capteur près du point le plus chaud de la bobine dans l'état normal de l'équipement. Il existe des fonctions telles que l'alarme de surchauffe de l'enroulement, enroulement lors d'un voyage à haute température, et alarme de surchauffe du noyau de fer.
Le signal analogique de température, alarme de surchauffe, voyage à haute température, and fan operation/failure information should be able to be sent to the substation’s integrated automation system and remote power dispatch system through a remote communication port. Information such as over temperature alarm, voyage à haute température, and fan operation/failure should be able to be output through communication or contact. If the device loses power or experiences a fault, it should have a hard contact signal output. It should have data storage function, so that all data will not be lost in case of device failure or power loss. It has remote communication function, and the communication interface adopts standard interfaces such as RS485, Modbus, CEI60870-5-103, etc..
Capteur de température à fibre optique, Système de surveillance intelligent, Fabricant de fibre optique distribué en Chine
![]() |
![]() |
![]() |
Capteurs de température à fibre optique INNO ,systèmes de surveillance de la température.