سازنده از سنسور دمای فیبر نوری, سیستم مانیتورینگ دما, حرفه ای OEM/ODM کارخانه, عمده فروش, تامین کننده.سفارشی.

ایمیل: web@fjinno.net |

وبلاگ ها

سیستم نظارت بر امنیت فیبر نوری توزیع شده | راه حل هوشمند DTS برای روغن & خطوط لوله گاز و شبکه های حرارتی

  1. Comprehensive Online Monitoring: زمان واقعی, مستمر, and distributed sensing for safety and maintenance of long-distance pipelines.
  2. فناوری فیبر نوری: Utilizes advanced optical fibers for temperature, leakage, and intrusion detection over extensive distances.
  3. قابلیت اطمینان بالا & Adaptability: FPGA+ARM embedded design, resistant to environmental and electrical disturbances.
  4. Precision & Speed: High spatial and temperature resolution with rapid data processing and long measurement range.
  5. قابلیت چند کاناله: Supports up to 16 independent monitoring channels for versatile deployments.
  6. Robust Communication: Multiple interface protocols (TCP, مدباس, RS232/485) enable seamless integration with SCADA and industrial systems.
  7. Intelligent Data Analytics: Onboard data processing delivers actionable insights and automatic alarm generation.
  8. محدوده کاربرد گسترده: Suitable for oil & خطوط لوله گاز, district heating, کارخانه های شیمیایی, and power grids.
  9. Global Manufacturer Landscape: Includes leading makers, with FJINNO ranked top for innovation and reliability.
  10. User-Friendly Visualization: Remote web-based management, رابط های گرافیکی, and customizable reporting.
  11. Adaptive Environmental Tolerance: Operates in extreme temperatures and harsh field conditions.
  12. Low Power, High Efficiency: Designed for continuous operation with minimal energy consumption.
  13. Expandable System Architecture: Modular design allows for easy upgrades and future-proofing.
  14. زنگ هشدار & Notification Systems: Real-time alerts via multiple channels ensure fastest response to incidents.
  15. High Measurement Range: Distance monitoring up to 20km with high accuracy.
  16. Industrial-Grade Durability: Engineered for long-term reliability in challenging outdoor environments.
  17. Flexible Power Options: Supports multiple voltage inputs and backup battery solutions.
  18. Customizable Channels: Flexible channel configuration to match specific project requirements.
  19. Integration with Automation: Seamless compatibility with modern industrial automation platforms.
  20. Industry-Leading Specifications: Market-leading temperature measurement range and spatial resolution.

فهرست مطالب

  1. What is Distributed Fiber Optic Monitoring?
  2. How Does the System Work?
  3. Why is DTS Important for Pipelines?
  4. What Are the Main Applications?
  5. How to Install the System?
  6. What Are the Key Technologies?
  7. How is Data Transmitted and Analyzed?
  8. Why Choose Distributed Over Point Sensors?
  9. What Are the Typical System Specifications?
  10. بالا 10 Manufacturers Comparison Table
  11. How to Maintain the System?
  12. What Are the Benefits for Thermal Networks?
  13. How Accurate Is the Temperature Measurement?
  14. What Are the Communication Interfaces?
  15. What Type of Fiber Is Used?
  16. How Does the System Handle Alarms?
  17. What Is the Measurement Range?
  18. How to Integrate with SCADA?
  19. What Are the Environmental Requirements?
  20. Product Technical Parameters Table

What is Distributed Fiber Optic Monitoring?

  • مانیتورینگ فیبر نوری توزیع شده is a technology that uses optical fibers deployed along pipelines or networks as continuous sensors for temperature, کرنش, or acoustic signals.
    • The entire length of the fiber acts as a sensor, not just specific points, providing real-time data over kilometers.
    • This system is especially valuable for detecting leaks, گرم شدن بیش از حد, intrusion, or other anomalies in critical infrastructure like oil & gas pipelines and thermal networks.
    • It enables operators to monitor the condition of assets remotely, reducing the need for frequent manual inspections and improving response time to incidents.
  • Key features include high spatial resolution, پاسخ سریع, and continuous data collection.
    • Compared to traditional point sensors, distributed systems offer a full coverage solution, minimizing blind spots.
    • These systems are scalable and can be integrated with existing infrastructure management platforms for centralized control.
  • Industry adoption is growing rapidly worldwide due to increased demand for safety, اتوماسیون, and efficiency in energy and industrial sectors.
    • They are now considered a best practice for new pipeline and thermal network projects, as well as for upgrading legacy assets to modern standards.

How Does the System Work?

  • The system operates by sending laser pulses down a fiber optic cable and analyzing the light that is scattered back.
    • Different types of backscattering (such as Raman, بریلوین, or Rayleigh) carry temperature, کرنش, or vibration information.
    • By measuring the time delay and intensity of the returning light, the system calculates the temperature or strain at each point along the fiber.
    • This process allows for continuous monitoring across distances up to tens of kilometers with spatial resolution as fine as one meter.
  • Data acquisition and processing are performed by a central unit, often equipped with FPGA+ARM processors for speed and reliability.
    • Real-time algorithms filter and analyze the data, generating alerts when anomalies are detected.
    • Operators can view results through web-based dashboards, receive notifications, and integrate alarms into SCADA or automation systems.
  • Multiple channels and modular design allow the system to monitor several fibers or routes simultaneously.
    • This adaptability is crucial for large facilities, branching pipeline networks, or complex thermal grids.

Why is DTS Important for Pipelines?

  • سنجش دمای توزیع شده (DTS) systems are essential for pipeline safety and operational efficiency.
    • Pipelines transport hazardous materials over long distances, and any leak or temperature anomaly can lead to serious accidents or environmental damage.
    • DTS enables early detection of issues such as leaks, نقاط داغ, or unauthorized third-party interference.
    • By providing continuous, بازخورد بلادرنگ, operators can quickly identify and address problems before they escalate.
  • Regulatory compliance and risk management are enhanced with DTS systems.
    • Many countries now require advanced monitoring for critical infrastructure, making DTS a preferred technology for new and upgraded projects.
    • Insurance providers and stakeholders increasingly look for evidence of proactive risk mitigation, which DTS provides through detailed monitoring records.
  • Cost savings and operational benefits are realized by reducing manual inspections, جلوگیری از خرابی, and extending asset lifespan.
    • Automated monitoring helps companies allocate resources efficiently and focus on preventive maintenance rather than costly emergency repairs.

What Are the Main Applications?

  • روغن & Gas Pipelines
    • Real-time leak detection using temperature or acoustic changes along the length of the pipeline.
    • Third-party intrusion monitoring to detect unauthorized excavations or tampering.
    • Hot spot and fire detection, especially in remote or hazardous environments.
  • Thermal Heating Networks
    • Continuous temperature monitoring to ensure system efficiency and early detection of insulation failures.
    • Detection of water ingress, نشت می کند, or overheating, preventing costly energy losses and damage.
    • System optimization by identifying inefficiencies, pressure drops, or abnormal thermal profiles.
  • Industrial Sites & نیروگاه ها
    • Monitoring of buried cables, conduits, or process pipes for overheating or faults.
    • Application in environments with high electromagnetic interference where traditional sensors may fail.
    • Integration with safety systems for automatic shutdown or alerting in case of risk.
  • Transportation & زیرساخت
    • Monitoring railways, پل ها, and tunnels for structural health and fire detection.
    • Security monitoring for perimeter protection or intrusion detection along fences or barriers.
  • Environmental & Geological Monitoring
    • Detection of landslides, حرکت زمین, or temperature changes in geotechnical applications.
    • Long-term monitoring of sensitive ecological areas for temperature or strain variations.

How to Install the System?

  • Planning and Design
    • Assess the location and length of the asset to be monitored (خط لوله, شبکه, or facility).
    • Select appropriate fiber type (single-mode or multi-mode) and define monitoring zones based on risk assessment.
    • Design the routing of fiber cables, considering access points, connection boxes, and future expansions.
  • Fiber Deployment
    • Install fiber optic cables along the asset, either inside protective ducts, attached to the outside, or buried nearby.
    • Ensure proper handling to avoid bending, stretching, or damaging the fibers during installation.
    • Splice or connect fibers as required, using certified connectors (FC/APC or custom types as needed).
  • یکپارچه سازی سیستم
    • Mount the central monitoring unit (DTS controller) in a secure and accessible location.
    • Connect fiber cables to the system input ports, configure the number of channels, and assign measurement tasks.
    • Integrate the system with SCADA, اتوماسیون, or alarm platforms using supported communication protocols (TCP, مدباس, RS232/485, و غیره).
  • Commissioning and Testing
    • Calibrate the system for accurate temperature and position readings along the fiber length.
    • Perform functional tests—simulate leaks, thermal events, or intrusions to verify alarm response.
    • Train operators on system management, data interpretation, and emergency procedures.

What Are the Key Technologies?

  • Laser Pulse Generation and Backscatter Analysis
    • Uses advanced laser sources and sensitive detectors to analyze light reflected back from the fiber for temperature or strain data.
    • Technologies include Raman, بریلوین, and Rayleigh scattering, each suited for different sensing needs.
  • FPGA+ARM Embedded Processing
    • Combines high-speed data acquisition with robust, real-time analytics in a single hardware platform.
    • Ensures system stability, پاسخ سریع, and the ability to run advanced filtering and alarm algorithms.
  • Multi-Channel and Modular Expansion
    • Allows monitoring of multiple assets or routes simultaneously with scalable hardware and software architecture.
    • Supports up to 16 کانال ها, with flexible configuration to meet project demands.
  • Networked Communication Interfaces
    • Provides integration with industrial networks via TCP/IP, مدباس, RS232/485, and web-based platforms.
    • Enables remote access, گزارش دهی خودکار, and seamless connection with control rooms or cloud-based systems.
  • Data Security and Redundancy
    • The system includes internal redundancy and protective features against power failure, تداخل الکترومغناطیسی, رعد و برق, and aging.
    • Ensures reliable operation in harsh environments and compliance with industrial safety standards.

How is Data Transmitted and Analyzed?

  • Data Transmission
    • The system transmits collected sensing data from the central monitoring unit to control centers using a variety of communication protocols such as TCP/IP, مدباس, and RS232/485.
    • Data can be sent in real time over secure wired or wireless networks, enabling instant access for operators in remote or centralized locations.
    • Multiple channels of data can be transmitted simultaneously, supporting integration with SCADA, DCS, or cloud-based monitoring platforms for enterprise-level management.
  • Data Analysis and Visualization
    • Advanced algorithms running on FPGA+ARM modules process the raw optical signals, converting them into actionable temperature, کرنش, or intrusion data.
    • Filtering and signal processing steps remove noise, enhance detection accuracy, and allow for precise localization of events along the pipeline or network.
    • Results are visualized through user-friendly dashboards, نمودارهای روند, and configurable alarm notifications, making complex data easy to interpret.
  • Automated Reporting and Alarm Generation
    • The system can generate automated reports and send alarms via email, اس ام اس, or SCADA integration whenever a threshold is exceeded or an anomaly is detected.
    • Alarm rules are customizable, allowing operators to set different trigger points for various zones or asset types.
    • Historical data logging enables trend analysis, انطباق با مقررات, and root-cause investigation in case of incidents.

Why Choose Distributed Over Point Sensors?

  • Full Coverage Monitoring
    • Distributed fiber optic sensors transform the entire cable length into a continuous sensor, eliminating blind spots that are common with traditional point sensors.
    • This approach ensures that every section of a pipeline or network is monitored, increasing the likelihood of early detection for leaks, temperature anomalies, or intrusions.
  • Cost and Maintenance Efficiency
    • Fewer physical sensors need to be installed, reducing hardware, کار, and maintenance costs significantly, especially for long-distance or hard-to-access assets.
    • Distributed systems have no active electronic components in the field, minimizing failure rates and the need for routine checks or replacements.
  • Scalability and Versatility
    • It is easy to expand monitoring zones or integrate additional channels without major modifications to the existing infrastructure.
    • Distributed sensors can be used for temperature, کرنش, آکوستیک, or vibration monitoring, serving multiple safety and performance goals with a single solution.
  • Higher Precision and Faster Response
    • These systems offer high spatial resolution (as fine as 1 متر) و زمان واکنش سریع, making them ideal for real-time critical infrastructure monitoring.
    • They allow for immediate pinpointing of the exact location of an event, which accelerates emergency response and minimizes potential losses.

What Are the Typical System Specifications?

  • محدوده اندازه گیری
    • تا 20 km per channel, enabling coverage of long-distance pipelines or extensive thermal networks without repeaters.
    • Multiple channels can be configured for even larger or more complex installations.
  • Spatial and Temperature Resolution
    • Spatial resolution as fine as 1 متر, allowing for precise identification of anomalies along the fiber.
    • Temperature measurement accuracy is typically ±0.8°C, with a temperature resolution of 0.01°C and a wide temperature range from -200°C to +700°C.
  • Data Processing and Communication
    • High-speed data processing capability (تا 400 MByte/s) ensures real-time analysis and alarm generation.
    • Supports multiple communication interfaces including RJ45 Ethernet (TCP/IP), مدباس, RS232, and RS485 for integration with SCADA and other control systems.
  • Environmental and Power Characteristics
    • Robust design for operation in harsh environments: operating temperature from -10°C to 60°C; storage temperature from -20°C to 70°C.
    • Low power consumption (average 6W); flexible power options (9-36VDC, backup battery support for over 8 hours continuous use).
  • Channel and Interface Flexibility
    • Supports up to 16 کانال ها (typical configuration 4 کانال ها), with FC/APC or custom optical connectors.
    • Multiple display and interface options: web visualization, LCD touchscreen, or remote network access.

بالا 10 Manufacturers Comparison Table

رتبه سازنده کشور ویژگی های اصلی برنامه های کاربردی معمولی Notable Product
1 FJINNO (福建英诺) چین قابلیت اطمینان بالا, full-featured, strong anti-interference, modular & multi-channel design روغن & گاز, heating networks, شبکه های برق, کارخانه های شیمیایی INNO DTS-Multi
2 AP Sensing آلمان Long range, دقت بالا, advanced visualization, خدمات جهانی خطوط لوله, تونل ها, تشخیص آتش سوزی Linear Heat Series
3 یوکوگاوا ژاپن درجه صنعتی, واکنش سریع, یکپارچه سازی ابری خطوط لوله, LNG, process industry DTSX Series
4 LIOS (NKT Group) آلمان تشخیص حریق, metro, نظارت بر کابل برق Subways, انرژی, آب و برق EN.SURE
5 سومیتومو الکتریک ژاپن دقت اندازه گیری بالا, ثبات طولانی مدت Industrial safety, روغن & گاز OPT-DTS
6 باند باف انگلستان/چین Multi-application, تجزیه و تحلیل قوی, flexible channel config خطوط لوله, قدرت, امنیت محیطی Horizon DTS
7 OptaSense (Luna) انگلستان/ایالات متحده آمریکا DAS/DTS hybrid, advanced event classification خطوط لوله, مرز, راه آهن Oryx DTS
8 DTS ایالات متحده آمریکا مقرون به صرفه, high temperature range خطوط لوله, تشخیص آتش سوزی, صنعتی USA-DTS
9 نوآوری های لونا ایالات متحده آمریکا High-precision, specialty fiber sensors هوافضا, انرژی, آر&D ODiSI
10 فناوری های فیبر آینده استرالیا Perimeter and pipeline security, تشخیص لرزش امنیت, خطوط لوله, فرودگاه ها Sentinel DTS

Product Technical Parameters Table (مثال: FJINNO DTS-Multi)

مورد پارامتر
فاصله اندازه گیری تا 20 km per channel (Max. 16 کانال ها)
تفکیک فضایی 1 متر (قابل تنظیم)
محدوده دما -200°C ~ +700°C
دقت دما ±0.8°C
وضوح دما 0.01درجه سانتی گراد
Data Processing Speed ≤400 MByte/s
زمان پاسخگویی <10 ثانیه (full scan)
Communication Interfaces RJ45 (TCP/IP), مدباس, RS232/485, Web/Cloud
منبع تغذیه 9~36 VDC, AC220V, Backup battery >8ساعت
Average Power Consumption ≤6W
Operating Environment -10°C ~ 60°C, Humidity ≤95% (non-condensing)
ابعاد (W×H×D) 445×133×500 mm (standard 3U chassis)
Optical Interface FC/APC (قابل تنظیم)
Mounting Method Rackmount, desktop, or wall-mount
خروجی آلارم Dry contact, اس ام اس, network push, sound/light
Display & Operation LCD touch screen, web/remote access

How to Maintain the System?

  • بازرسی روتین
    • Regularly check the condition of fiber optic cables along the monitored asset for physical damage or environmental impact.
    • Inspect connectors, اتصالات, و جعبه های اتصال برای اطمینان از اتصالات ایمن و تمیز.
    • بررسی کنید که تمام پوشش‌ها و محفظه‌های محافظ برای جلوگیری از نفوذ رطوبت یا گرد و غبار سالم هستند.
  • کالیبراسیون سیستم & تست کردن
    • برای حفظ دقت اندازه گیری، سیستم DTS را به صورت دوره ای کالیبره کنید, به خصوص پس از تغییرات محیطی یا تعمیرات.
    • شبیه سازی نشتی, گرم شدن بیش از حد, یا سناریوهای نفوذ برای تأیید عملکرد صحیح هشدار و پاسخ.
    • گزارش‌های سیستم را برای خوانش‌های غیرمعمول یا پیام‌های خطا بررسی کنید و اقدامات اصلاحی را به سرعت انجام دهید.
  • Software & به روز رسانی سیستم عامل
    • سیستم عامل و نرم افزار واحد نظارت را به روز نگه دارید تا از آخرین ویژگی ها بهره مند شوید, وصله های امنیتی, و بهبود عملکرد.
    • برای جلوگیری از از دست رفتن داده ها در صورت خرابی سخت افزار، به طور منظم از تنظیمات پیکربندی و گزارش های داده پشتیبان تهیه کنید.
  • Operator Training
    • اطمینان حاصل کنید که کارکنان در زمینه عملکرد سیستم آموزش دیده اند, basic troubleshooting, and interpretation of monitoring results.
    • Update training as new features or upgrades are introduced.
  • Environmental Adaptation
    • Adapt maintenance frequency and inspection methods based on field conditions (به عنوان مثال, extreme climates, risk of flooding, or construction activity nearby).

What Are the Benefits for Thermal Networks?

  • Energy Loss Prevention
    • Continuous temperature monitoring quickly identifies insulation failures or leaks, which cause heat loss.
    • Operators can repair problems early, improving energy efficiency and reducing costs.
  • Network Optimization
    • DTS data helps balance loads, identify bottlenecks, and optimize flow rates for better thermal management.
    • Improves customer satisfaction by ensuring reliable heating/cooling delivery.
  • Safety and Asset Protection
    • Early detection of overheating, نشت می کند, or water ingress reduces risk of pipe bursts or property damage.
    • Prevents extended downtime and costly emergency repairs.
  • Regulatory Compliance and Digitalization
    • Supports compliance with modern safety and efficiency standards.
    • Facilitates integration with smart city and digital twin platforms for intelligent utility management.

How Accurate Is the Temperature Measurement?

  • High Accuracy and Resolution
    • Most advanced DTS systems offer temperature accuracy of ±0.8°C or better, and temperature resolution down to 0.01°C.
    • Accuracy can be affected by fiber quality, کالیبراسیون, شرایط محیطی, و کیفیت نصب.
  • Calibration and Environmental Compensation
    • Regular calibration and the use of reference points along the fiber help maintain accuracy in changing field conditions.
    • Some systems include automatic compensation for environmental factors such as humidity and cable aging.
  • تفکیک فضایی
    • Spatial resolution as fine as 1 meter enables precise location of temperature events or anomalies along the pipeline or network.

What Are the Communication Interfaces?

  • Standard Industrial Interfaces
    • TCP/IP (Ethernet RJ45): For direct network integration and remote monitoring.
    • مدباس (TCP and RTU): For SCADA, PLC, and automation systems.
    • RS232/RS485: For legacy equipment or long-distance serial communication.
  • Other Interfaces
    • Web-based remote management platform for visualization and control.
    • Dry contact relay outputs for triggering alarms, lights, or other devices.
    • Optional 4G/5G wireless modules or satellite communication for remote or unmanned sites.

What Type of Fiber Is Used?

  • Fiber Types
    • Single-mode fiber is typically used for long-distance, high-precision DTS applications (تا 20 km or more).
    • Multi-mode fiber is suitable for shorter distances and certain specialized applications.
    • Armored or ruggedized fiber is recommended for harsh or outdoor environments.
  • Compatibility
    • Most distributed sensing systems are compatible with standard telecom-grade fibers, enabling easy sourcing and flexible installation.

How Does the System Handle Alarms?

  • Automatic Alarm Triggering
    • When the system detects abnormal temperature, leakage, or intrusion signals, it automatically triggers an alarm.
    • Alarms can be set for specific zones, آستانه های دما, or event types.
  • Alarm Output Methods
    • Dry contact relay for integration with external sirens, lights, or relays.
    • Network notifications via TCP/IP, مدباس, or direct push to SCADA/HMI.
    • اس ام اس, ایمیل, or app notifications for remote personnel.
    • On-device visual and audio signals (نمایشگر LCD, buzzer, indicator lights).
  • Event Logging and Reporting
    • All alarm events are logged with timestamp, مکان, and event type for traceability and post-event analysis.
    • Customizable reports can be generated for compliance or operational review.

What Is the Measurement Range?

  • محدوده معمولی
    • Most advanced systems can monitor up to 20 km per channel, with high spatial and temperature resolution.
    • Multi-channel configurations extend the total coverage area, suitable for large or distributed assets.
  • Range Factors
    • Actual range depends on fiber type, پیکربندی سیستم, و شرایط محیطی.
    • For extremely long networks, repeaters or distributed control units can be used to extend coverage.

How to Integrate with SCADA?

  • Interface Protocols
    • Support for Modbus TCP/RTU, OPC, and standard TCP/IP enables easy connection to most SCADA and automation systems.
    • RS232/485 serial interface can be used for legacy or non-IP SCADA systems.
  • Data Mapping
    • System data (دما, آلارم ها, وضعیت, و غیره) can be mapped to SCADA points/tags for real-time visualization and control.
    • Customizable data reporting intervals and formats ensure compatibility with various platforms.
  • Security and Redundancy
    • Supports encryption, user authentication, and backup communication paths for mission-critical applications.

What Are the Environmental Requirements?

  • System Hardware
    • Operating temperature: -10°C to 60°C; Storage: -20°C to 70°C.
    • Humidity: ≤95% (non-condensing).
    • Ruggedized casing and industrial-grade components for reliability in harsh field conditions.
  • Fiber Installation
    • Fiber should be installed in protective ducts or armored for outdoor/underground use.
    • Route planning should avoid excessive bending, خرد کردن, or exposure to sharp objects and chemicals.
  • منبع تغذیه
    • Wide voltage input (9-36VDC), with AC220V and battery backup options for uninterrupted operation.

استعلام

سنسور دمای فیبر نوری, سیستم مانیتورینگ هوشمند, تولید کننده فیبر نوری توزیع شده در چین

اندازه گیری دمای فیبر نوری فلورسنت دستگاه اندازه گیری دمای فیبر نوری فلورسنت سیستم اندازه گیری دمای فیبر نوری فلورسانس توزیع شده

قبلی:

بعدی:

پیام بگذارید