Due to the long power supply distance, multiple equipment components, high electrical load, and mostly continuous operation of 10kV distribution lines, the electrical equipment of substations that supply power to the lines has the characteristics of heavy load and high current during operation. Under such conditions, when the connection screws of the substation equipment become loose or the components of each part have poor contact, the temperature of the equipment will abnormally rise due to the continuous passage of high current, resulting in poor material performance of the electrical equipment. If not detected and repaired in a timely manner, serious accidents may occur due to overheating and melting of the welding points of the equipment. Es decir, during the occurrence of faults in high-voltage equipment, habrá un aumento significativo de la temperatura. Por lo tanto, Es muy importante monitorear los parámetros de temperatura de los equipos de alto voltaje durante el funcionamiento..

Razones del aumento de temperatura a alta presión

El equipo eléctrico completamente cerrado de la subestación se refiere a la combinación de componentes de alto voltaje, como disyuntores de alto voltaje., interruptores de aislamiento, y transformadores, que se instalan en gabinetes cerrados de metal, como aparatos eléctricos combinados y aparamenta de alta tensión. Durante la operación de equipos eléctricos completamente cerrados., si se produce una descarga parcial en el equipo interno del gabinete, Puede causar un aumento anormal de temperatura en la conexión del conductor.. Debido a la posición de calefacción oculta, el personal operativo no puede detectarlo a tiempo. Esto puede expandir fácilmente la falla., causing electrical components to break down and burn out, and affecting adjacent equipment units, resulting in a malignant power outage accident.

The reason for the temperature rise of high-voltage circuit breakers is that the circuit breaker temperature is too high

During the normal operation of high-voltage circuit breakers, the energy generated by the long-term working current is converted into thermal energy, causing the temperature of electrical materials to rise but not exceed the specified range; When the conductive circuit is abnormal, it will cause the temperature of the electrical material to increase beyond the specified range, accelerate the oxidation of the dynamic and static contacts, increase the contact resistance, and further increase the heating temperature, resulting in a decrease in the mechanical and physical properties of the electrical material. When the temperature exceeds the melting point of the material, it will cause the two contacts to melt, ultimately leading to an electrical accident where the circuit breaker cannot be opened. Por ejemplo, the metal armored enclosed switchgear in substations (switching stations) all use small car type circuit breakers. When the handcart plug is pushed in, if the force is not enough or not shaken in place, it will cause poor contact between the dynamic and static plugs, causando sobrecalentamiento. Durante la operación, the contact will melt, which can cause phase to phase short circuits and lead to a malignant accident of the overall switch burning.

The reason for the high temperature of the busbar is the temperature rise of the electrical contacts

La conexión entre diversos equipos eléctricos en la subestación se basa principalmente en tornillos para engarzar., así como varios métodos, como la conexión con la barra colectora principal y la barra colectora secundaria.. Debido a la limitación del nivel de voltaje., es necesario considerar los requisitos para la distancia segura a tierra y el funcionamiento seguro de las barras colectoras de conexión. Por lo tanto, se ha instalado y cerrado una funda aislante. Esto hace que los cables de conexión entre dispositivos tengan muchas características que no favorecen el funcionamiento., tales como una alta distancia de instalación desde el suelo y un fuerte sellado. Si los tornillos en la conexión no se mantienen adecuadamente o funcionan durante mucho tiempo, Factores externos como la fuerza del viento y la vibración de la energía eléctrica durante el funcionamiento pueden hacer que los tornillos se aflojen y se oxiden., resulting in overheating of the contact points at the busbar connection due to excessive contact resistance, which can lead to a malignant accident of large-scale power outage in the entire substation or section of the busbar.