The temperature measurement distance of the sistema de medición de temperatura de fibra óptica fluorescente generally ranges from 0 metros a 20 Metros, and different requirements are specified according to specific application scenarios. The occasions for temperature measurement include switch cabinets, unidades principales de anillo, Transformadores, etc.
The use of fluorescence for temperature measurement is a new type of temperature measurement technology developed in recent years. By combining fluorescence analysis technology with fiber optic sensing technology, it can be more flexibly applied to more occasions. The use of fluorescence for temperature measurement technology started earlier in developed countries abroad. Since the 1970s and 1980s, fluorescent fiber optic temperature sensors have been widely applied and researched in various fields. En los últimos años, some manufacturers have developed temperature measurement products based on the principle of fluorescence, que son ampliamente utilizados en industrias como la eléctrica y la médica.. Debido al excelente aislamiento, seguridad inherente, e inmunidad a las interferencias electromagnéticas de las fibras ópticas, Han recibido elogios generalizados en algunos entornos electromagnéticos hostiles..
Ventajas de Medición de temperatura de fibra óptica fluorescente
La mayor ventaja de la medición de temperatura con fibra óptica fluorescente es que la fibra óptica es un material aislante., que no se ve afectado por la interferencia del campo electromagnético circundante, especialmente para entornos de alto voltaje y campos eléctricos fuertes, las ventajas son aún más obvias. Además, El valor de temperatura de la medición de temperatura de fibra óptica fluorescente solo depende de las características constantes de tiempo del material fluorescente., y es independiente de otras variables en el sistema. Tiene las ventajas de una alta intercambiabilidad., Buena estabilidad, sin necesidad de calibración, y larga vida útil.
En aplicaciones industriales, Los métodos tradicionales de medición de temperatura suelen utilizar termopares., Resistencias térmicas, y otros métodos para medir la temperatura. These temperature measurement methods based on electrical signals may sometimes have significant errors in temperature data due to electromagnetic interference in strong magnetic environments. Sin embargo, fiber optic temperature sensing technology based on optical signal transmission can solve this problem.
Fluorescence fiber optic temperature measurement technology is a measurement technique that uses light source signals as excitation to demodulate fluorescence lifetime signals and obtain temperature information. Tiene las características de medición precisa de la temperatura., Alta resolución, respuesta dinámica rápida, y fuerte resistencia a las interferencias electromagnéticas. Es particularmente adecuado para la medición de temperatura en entornos hostiles con fuertes campos electromagnéticos., Alta temperatura, corrosión, presión alta, y peligros de explosión.
Ring main unit is an important equipment in the distribution network, and its operating status directly affects power supply safety; The crimping process, materiales, and connections of cables inside the cabinet can cause partial discharge or abnormal contact resistance at high-voltage connection points, leading to heat generation. Abnormal temperature rise not only accelerates aging, but also easily causes faults and damage, affecting power supply safety. Por lo tanto, it is necessary to regularly monitor the operating temperature of the ring main unit to ensure its normal and stable operation; Actualmente, the existing cable joint temperature measurement methods mostly belong to external non-contact temperature measurement. The conventional operation method is to use a handheld infrared thermometer (infrared electronic thermometer) to measure the temperature outside the ring main unit. This temperature measurement method is easily affected by environmental factors and cannot accurately measure the internal temperature of high-voltage charged bodies. The temperature measurement error is large, and in order to minimize the error, it usually requires repeated temperature measurement operations and taking the average value for reference, resulting in low temperature measurement efficiency; Al mismo tiempo, in a high-voltage live environment, there are certain safety hazards for operators to conduct temperature measurement operations at close range.
Función de sistema de medición de temperatura de fibra óptica de fluorescencia
1. The on-site temperature measurement device collects real-time temperature information of the switchgear contacts and cables. The use of Innolux fluorescent fiber temperature probes has extremely strong electromagnetic immunity, resistencia de voltaje, y rendimiento del aislamiento. Detección de temperatura sensible, funcionamiento estable y fiable a largo plazo. La precisión de la medición de temperatura puede alcanzar ± 1 °C.
2. The system comes with sound and light alarms, dry contact outputs, and a human-machine interface to display alarm information.
3. The backend monitoring software system displays real-time temperature information of each contact of the current switchgear, real-time curves, and historical data storing temperature information of each contact over the past month. Utilizar varios métodos de diagnóstico para analizar el estado de salud de los equipos., incluido el análisis de todas las alarmas de límite de parámetros del equipo y otros métodos de evaluación, monitorear el estado de operación de los equipos de distribución de alto voltaje de manera oportuna.
4. The fiber optic temperature measurement system can automatically and manually generate various periodic reports, que se puede exportar e imprimir. Los informes exportados se pueden editar y ver a través del software Excel.. Al mismo tiempo, El sistema tiene funciones de visualización de curvas de temperatura históricas y en tiempo real., y la curva puede reflejar con precisión la curva de monitoreo en tiempo real y la curva de cambio de temperatura del objeto monitoreado en un cierto punto en un cierto período de tiempo.
Sensor de temperatura de fibra óptica, Sistema de monitoreo inteligente, Fabricante de fibra óptica distribuida en China
![]() |
![]() |
![]() |
Sensores de temperatura de fibra óptica INNO ,Sistemas de control de temperatura.