Why does the bus duct need temperature measurement
Closed busbar trunking (abbreviated as busbar trunking) is widely used in power supply systems of high-rise buildings and buildings. But with the rapid increase in electricity consumption, the heating of the bus duct is particularly severe, especially at the connection head, which seriously affects the normal operation of the bus duct and requires real-time monitoring of electricity safety. Traditional temperature sensing cables have serious defects in the setting, quantification, posicionamiento, and reusability of temperature alarm points, which cannot meet the needs of production process management. Sin embargo, high-precision point type thermometers or thermocouples cannot solve the needs of linear and continuous monitoring.
¿Cuáles son las ventajas de fibra óptica distribuida sistemas de medición de temperatura
El sistema distribuido de monitoreo de temperatura de fibra óptica adopts a brand new design, with good performance indicators and system stability. This system is developed based on the principles of backward Raman scattering and optical time-domain reflection (OTDR) posicionamiento, and has functions such as optical signal generation, spectral analysis, photoelectric conversion, amplificación de señal, and processing. The system uses dedicated temperature sensing optical cables as temperature sensors, integrating computer, comunicación de fibra óptica, detección de fibra óptica, control optoelectrónico y otras tecnologías. It has inherent safety, resistencia a la corrosión, y no se ve afectado por interferencias electromagnéticas. It continuously monitors long-distance and large-scale environmental temperature information.

Characteristics of Distributed Fiber Optic Bus Channel Temperature Monitoring System
Using distributed fiber optic temperature sensing equipment to sense cable temperature and position information for signal detection and transmission, achieving no electricity detection and intrinsic safety explosion-proof;
Uso de sensores de temperatura distribuidos avanzados por fibra óptica como unidad de medida, con tecnología avanzada y alta precisión de medición:
Los cables ópticos de detección de temperatura distribuida tienen un rango de temperatura de funcionamiento a largo plazo de -40 ℃ a 150 ℃, con un máximo de 200 ℃, and a wide range of applications;
Adopción de un método de medición de detector de bucle único, simple installation and low cost; Can reserve spare cores;
Real time display of temperature in various zones, y la capacidad de mostrar datos históricos y cambiar curvas, así como los cambios de temperatura promedio:
The system has a compact structure, instalación sencilla, y mantenimiento conveniente;
A través de software, different warning and alarm values can be set according to actual situations; The alarm methods are diverse, incluyendo alarma de temperatura constante, alarma de tasa de aumento de temperatura, y alarma de diferencia de temperatura.
A través de software, data can be queried: point by point query, alarm record query, interval query, consulta de datos históricos, e impresión de informes.
On site installation diagram of distributed fiber optic bus duct
![]() |
![]() |
![]() |
Distributed fiber optic temperature measurement software interface
Provide a user-friendly and easy-to-use fiber optic temperature monitoring application software. The software mainly includes functional modules such as temperature monitoring, alarma de incendios, and visual display.
Temperature curve display
The system can display the real-time temperature distribution curve of the entire optical cable, and when there is an abnormal temperature at a certain location, the curve can show whether the temperature at that location increases or decreases.
Historical temperature statistics
Provide historical temperature data statistical analysis function, provide temperature change trends, incluido:
(1) The temperature distribution curve at different positions of the cable at a certain moment;
(2) The temperature change curve of a cable at a certain point on a certain day;
(3) The temperature change curve at a certain point of the cable during a certain period of time;
(4) The curve of the highest temperature change on a certain day.
Alarma de sobre temperatura
Provide various flexible fire alarm methods such as fixed temperature, aumento de temperatura, and regional temperature difference, and the alarm parameters can be graded and set by region. When the measured temperature exceeds the threshold temperature, the system will automatically emit alarm signals such as sound, LED indicator lights, text, and images. If multi-level temperature alarm (such as initial alarm at 30 ℃, pre alarm at 40 ℃, and measures taken at 50 ℃) and temperature rise rate can be set, temperature correction can be made according to different environments. The set value of temperature rise rate can be determined by on-site monitoring.
Visual interface
Provide a visual display interface that maps the fiber optic position to the image through a graphical configuration module. Once a temperature anomaly occurs at a certain point of the fiber optic, the alarm information is directly displayed on the image, making it visually appealing.
![]() |
![]() |
![]() |