Overview of solutions for fluorescent fiber optic temperature controllers for dry-type transformers
The measurement range specified in the “جهاز التحكم الإلكتروني في درجة الحرارة للمحولات” (جي بي/T7631-2016), which uses Pt100 as the traditional temperature sensor, يمكن أن يقتصر فقط على أقل من 1000 فولت, and this sensor is made of metal material, which poses a safety hazard. لذلك, temperature sensor probes and leads for measuring transformer winding temperature have higher requirements.
The fiber optic temperature controller uses our company’s independently developed مستشعر درجة حرارة الألياف الضوئية الفلورسنت كعنصر استشعار درجة الحرارة. عنصر استشعار درجة الحرارة هذا محصن ضد التداخل الكهرومغناطيسي ومقاوم للجهد العالي (100KV/الألياف إلى الأرض مسافة الرصاص 0.4 متر). Fluorescent fiber optic temperature measurement completely solves potential safety hazards from the source of temperature measurement and improves the safety level of transformers.
Target of نظام قياس درجة حرارة الألياف الضوئية الفلورية للمحولات من النوع الجاف
For the operating environment of dry-type transformers, يتم تحقيق العزل والحماية من إشارات التداخل الكهربائي الخارجية من مصدر الطاقة, نهاية إدخال الإشارة, نهاية إخراج الإشارة, وقذيفة صندوق التحكم في درجة الحرارة.
No metallic substances, السلامة الجوهرية.
استجابة للاهتزاز, تراب, رُطُوبَة, oil and other on-site working environments, multi-layer protective measures are taken to ensure that the fiber optic تحكم في درجة الحرارة has good electromagnetic compatibility, ensuring stable and reliable operation.
Design principles of fluorescent fiber optic temperature measurement host for dry-type transformers
مبدأ التطبيق العملي
يلتزم بناء النظام بمبدأ التطبيق العملي. على أساس التطبيق العملي, التقدم والبصيرة تعتبر, والمعيار, advanced and mature products and development platforms are selected to build a system that is practical and solves practical problems.
Standardization principle
The system software and hardware platforms and application development tools used in application construction should comply with national standards, standards of the Ministry of Information Industry, relevant technical specifications and requirements of the company.
The principle of uniformity
Following the policy of centralized information management, overall planning, overall design, and step-by-step implementation, the implementation process embodies four unified principles: unified leadership, unified planning, unified standards, and unified organization and implementation.
Reliability principle
The software and hardware resources need to ensure the uninterrupted and reliable operation of the نظام قياس درجة حرارة الألياف الضوئية ل 7 × 24 ساعات. لذلك, it is necessary to equip a complete design of reliability measures to ensure the highly reliable operation of the system and fully consider the reliability requirements of key system applications.
Reliable security mechanism
This system adopts a series of secure encryption measures, with a built-in 64 bit encryption algorithm. The system has higher security and can effectively prevent data leakage and theft, ensuring the security, دقة, and integrity of the system’s data, and preventing illegal operator operations and legitimate operator illegal operations.
The operation interface is simple, friendly, and highly intelligent
The system automatically checks the legality of the input data and provides friendly prompts for operator errors.
Stable operation and reliable data.
The platform is easy to operate, easy to master, and the installation process is simple. Data can be automatically generated into various reports as needed, improving management efficiency.
Principle of Fluorescent Fiber Optic Temperature Measurement
The fiber optic probe consists of three parts: ST connector, كابل الألياف الضوئية, and end temperature sensing end. The ST connector is the connection part with the photoelectric module; Fiber optic cable is the transmission part, with quartz fiber inside. The quartz fiber has a coating and cladding on the outside, and a Teflon protective sleeve on the outermost part; The end temperature sensing end contains temperature sensitive rare earth materials, which excite fluorescence after being irradiated by fixed wavelength light. بعد توقف الإثارة, the relationship between the decay time constant of fluorescence afterglow and temperature is a quasi exponential function. The temperature can be obtained by measuring the time constant of afterglow; The optical fiber is resistant to high temperatures of 200 ℃ and has an outer diameter of 3mm. Long term bending radius of 13.2cm. Short term bending radius 4.4cm
The sensor probe material is rare earth fluorescent material, and its biggest advantage compared to other optical fiber temperature measurement principles is that temperature measurement is independent of light intensity. It has strong compatibility with the inconsistency of fluorescence intensity, optical path attenuation, and circuit drift in hardware. لذلك, it is not affected by electromagnetic interference and can withstand high voltage, making it very suitable for high voltage, strong magnetic field, flammable and explosive temperature measurement occasions.
Introduction to wiring and installation of fiber optic temperature controllers for dry-type transformers
1.1 Structural framework
The system consists of three parts: a fluorescent fiber optic temperature controller, a fluorescent fiber optic probe, and fiber optic communication software.
The data transmission between the backend system and the temperature measurement terminal adopts RS485 communication method.
All data collection, إدارة, and temperature display are completed by communication software, and the system mainly realizes data collection and monitoring of temperature measurement. The fiber optic temperature measurement terminal integrates multi-channel fluorescent optical fibers, providing external RS485 communication, مكافحة التدخل, and corrosion-resistant design.
Application functions of fiber optic temperature controller system for dry-type transformers
1.1 مراقبة في الوقت الحقيقي
The data collection density can be set according to customer needs, and the system will collect data regularly based on the set parameters. ثم, it will be displayed in table form or curve drawing to achieve real-time monitoring. Real time monitoring of equipment operation status; مراقبة وتسجيل درجة حرارة المفاعل في الوقت الحقيقي.
1.2 الوظائف الأساسية
1) استعلام بيانات درجة الحرارة
1. يمكنك الاستعلام عن بيانات درجة الحرارة لتواريخ محددة, تصفح, مطبعة, والتصدير إلى Excel.
2) تخزين بيانات درجة الحرارة التاريخية
1. تسجيل بيانات درجة الحرارة بشكل دائم
مقدمة للتحكم في درجة حرارة الألياف الضوئية للمحولات من النوع الجاف
2.1 الميزات الرئيسية
يتم تضمين وحدة التحكم في درجة حرارة الألياف الضوئية في التثبيت. يتمتع هذا المنتج بمزايا تقنية فريدة في قياس درجة الحرارة في بيئات خاصة مثل الجهد العالي, التدخل الكهرومغناطيسي القوي, إلخ. نقطة ساخنة لدرجة الحرارة وإشارة القياس تستقبل جزءًا من الفلورسنت مستشعر درجة حرارة الألياف الضوئية لا تستخدم التوصيلات الكهربائية, والتي يمكن أن تعمل بدقة عالية وثبات لفترة طويلة, تحسين نطاق تطبيقه بشكل كبير. تتميز وحدة التحكم في درجة الحرارة بالألياف الضوئية بدقة وحساسية عالية, مقاوم للضغط العالي ويمكن مراقبته عن بعد, لديه عمر طويل, صغير الحجم, يجعل صيانة الأدوات بسيطة ومريحة, ويضمن النقل الآمن.
2.2 Main functions
توفير ثلاثة قياس درجة الحرارة المتعرجة; وظيفة مروحة التبريد التلقائية / اليدوية; وظيفة التعويض الرقمي لقيم العرض لكل قناة
The digital tube displays the temperature of the transformer’s hot spot on a circuit;
توفير وظيفة الصندوق الأسود, والتي يمكنها تسجيل بيانات درجة الحرارة ودرجة الحرارة القصوى التاريخية قبل انقطاع التيار الكهربائي ثلاث مرات;
Provide transformer door cabinet point opening alarm function;
Provide functions such as over temperature alarm, fault alarm, رحلة, إلخ
توفير وظيفة الاتصال RS485, communication with time mark can receive timing or MODBUS-RTU protocol (وظيفة F)
2.3 ميزات إضافية
يمد 4 وظائف الإخراج الحالية التناظرية المستقلة 4-20mA; (وظيفة E)
PTC المقاومة غير الخطية وظيفة حماية قياس درجة الحرارة; (وظيفة ج)
وظيفة التنبيه لمعدل ارتفاع درجة حرارة الملف ومعدل ارتفاع درجة حرارة قلب الحديد;
يمكن أن يعتمد بروتوكول الاتصال أساليب مثل Profibus, IEC60870-5-103, اتصالات إيثرنت, إلخ;
مستشعر درجة حرارة الألياف الضوئية, نظام مراقبة ذكي, الشركة المصنعة للألياف الضوئية الموزعة في الصين
![]() |
![]() |
![]() |
أجهزة استشعار درجة حرارة الألياف الضوئية INNO ,أنظمة مراقبة درجة الحرارة.