Why do reactors need to use fluorescent fiber optic temperature measurement systems
When the reactor sends abnormal or faulty signals, the faulty area of the reactor heats up and the temperature rises. By monitoring the temperature, the operating status of the reactor can be determined, thereby achieving the goal of protecting the reactor. General temperature measurement devices cannot measure the internal temperature of reactors. To solve this problem, فيجينو نظام قياس درجة حرارة الألياف الضوئية الفلورية can solve it through its anti-interference and high-temperature and high-pressure resistance characteristics.
Introduction to Fiber Optic Temperature Measurement System for Reactors
The IF-DK series reactor optical fiber temperature measurement adopts a fluorescent optical fiber temperature measurement device. The sensing probe of this device is made of non-metallic material and quartz optical fiber, which has complete electrical insulation and is not affected by high voltage and strong electromagnetic fields. It is resistant to chemical corrosion and pollution, and has fast response speed, تركيب بسيط, and high temperature resistance. The backend software is used for real-time online monitoring. The system consists of three parts: a fluorescent fiber optic تحكم في درجة الحرارة, a fluorescent fiber optic probe, and fiber optic communication software.
| basic function (Conventional D-type) |
1. Three winding temperature measurement; Automatic/manual start/stop of cooling fan; Temperature display value compensation function for each channel 2. Provide black box function, which can record the temperature data of the last power outage and the highest historical temperature; 3. Digital tube display; 4. Provide transformer door cabinet point opening alarm function; 5. Provide 1 set of over temperature alarm contacts (1 normally open, 1 normally closed); 6. Provide 1 set of over temperature trip contacts (1 normally open, 1 normally closed); 7. Provide 1 set of fan remote transmission contacts (1 normally open, 1 normally closed); 8. Provide 1 set of temperature controller fault alarm contacts (1 normally open, 1 normally closed); |
| Customized features (Customizable for special needs) |
1. Provide 1 iron core temperature measurement and 2 الحديد الأساسية على الاتصالات إنذار درجة الحرارة (1 normally open, 1 normally closed) (أنا أعمل); 2. توفير وظيفة الاتصال RS485, التواصل مع علامات الوقت, قادرة على تلقي مزامنة الوقت, بروتوكول مودبوس-RTU (وظيفة F); 3. وظيفة تشخيص خطأ المروحة وتوفير جهات اتصال إنذار لخطأ المروحة (وظيفة L); 4. Provide 4 وظائف الإخراج الحالية التناظرية المستقلة 4-20mA (وظيفة E); 5. توفير قياس درجة الحرارة والتحكم فيها لبيئة غرفة الكمبيوتر بأكملها; (وظيفة G) 6. وظيفة التنبيه لمعدل ارتفاع درجة حرارة الملف ومعدل ارتفاع درجة حرارة قلب الحديد; 7. يمكن أن يعتمد بروتوكول الاتصال أساليب مثل Profibus, IEC60870-5-103, اتصالات إيثرنت, إلخ; |