The manufacturer of Fibre Optic Temperature Sensor, Temperature Monitoring System, Professional OEM/ODM Factory, Wholesaler, Supplier.customized.

E-mail: web@fjinno.net    |    

Transformer Monitor/TempMerature Monitoring/

Dry Type Transformer Temperature Monitor & Controller YN-XP502F-3T

Intelligent Monitoring Device for Dry-Type Transformer

  • 3-channel PT100 temperature monitoring system for real-time winding temperature tracking
  • Reliable dry type transformer temperature controller with automatic over-temperature alarm and trip
  • 2.8-inch color LCD touch screen for intuitive transformer monitor operation
  • ARM-based CPU with modular circuit design for stable, interference-resistant monitoring
  • Standard MODBUS-RTU communication for easy integration with remote monitoring systems
  • Customizable channel count, alarm thresholds and communication settings available
  • Talk to our engineers for a tailored dry type transformer temperature indicator solution
  • Product Details

The YN-XP502F-3T is an intelligent temperature monitoring system designed specifically as a dry type transformer temperature controller. As a dedicated transformer monitor, this thermostat is specially customized for dry-type transformer applications: the thermostat is an embedded installation with strong anti-disturbance ability. It has unique technical advantages in temperature measurement under special environments such as high voltage and strong electromagnetic interference, and has reliable EMC and EMI performance. It has the characteristics of large output contact capacity, complete function, color LCD display interface with pictures and texts, etc., and is simple to set and easy to operate.

Manufactured by Fuzhou Innovation Electronic Scie&Tech Co., Ltd., this dry type transformer temperature indicator combines precise multi-channel temperature monitoring with an intuitive touchscreen interface, making it a reliable choice for substations, distribution rooms and industrial power systems that demand continuous, accurate temperature monitoring.

intelligent-monitoring-system-for-dry-type-transformers

Product Features

Feature Description
3-Channel PT100 Temperature Sensor Input 3-channel PT100 temperature measurement: 3-channel winding temperature measurement, and 1 channel for core temperature measurement
Color Touch Display Equipped with 2.8-inch color LCD touch screen
Stable Processing Core Utilize a CPU based on the ARM architecture, renowned for its robust data processing capabilities and system stability
Modular Circuit Design The circuit board design philosophy adopts a modular approach, with a clear separation of strong and weak currents to prevent spatial crosstalk
Remote Monitoring Ready Standard MODBUS-RTU communication protocol for seamless integration into a broader transformer monitoring system

Basic Technical Parameters

Item Parameter
Working environment Ambient temperature: -25℃ ~ +55℃; Ambient humidity: ≤95%(25℃)
Working power supply AC/DC 24~240V
Working frequency 50Hz or 60Hz(±2Hz)
Measurement range -30.0℃ ~ 240.0℃
Measurement accuracy ±1%FS(thermostat level of 0.5 class, sensor of B class)
Resolution 0.1℃
Fan contact capacity 16A/250VAC
Power ≤10W
Installation Embedded installation
Overall dimension 96×96×84mm (L×W×H)
Opening size 90×90mm (L×W)
Communication protocol Standard MODBUS-RTU (Address 1~247, Baud rate 1200~38400, default 9600)

Standards & Certifications

Production standard: JB/T7631-2016 《Electronic thermostat for Transformers》 Industry standards.

Certification standards: ISO9001:2015 International Quality Management System certification; ISO14001:2015 Environmental Management System Certification; ISO45001:2018 Occupational Health And Safety Management System Certification.

Test standards: IEC61000-4:2005 International Standards; GB/T17626-2008 《Electromagnetic Compatibility Test And Measurement Technology》 Standard.

Liquid Crystal Display Interface

After the initialization process is completed, this transformer monitor automatically proceeds to the “Main Interface,” and upon successful connection, it automatically reads the temperature. The display interface refreshes the temperature information every 1000ms, giving operators a live view of the temperature monitoring system at all times.

Temperature Display Area

The main interface simultaneously displays real-time readings from CH1, CH2 and CH3, with distinct color coding for different operating states so that abnormal conditions can be identified at a glance:

Display information Normal display status Temperature controller failure Sensor broken line Over-temperature alarm Over-temperature trip
Content 45.5 -ER- -OP- 130.0 152.0

When a device failure occurs (temperature exceeding the upper and lower limits of the temperature controller), the screen displays -ER-. When the sensor is in an open circuit condition, the screen displays -OP-. The buzzer sounds an alarm whenever any of the above states occur; when an alarm is triggered, the mute button will flash, and pressing it will cancel the buzzer alarm.

Clock Display Area

The real-time clock is shown at the top of the main screen. Tapping this area opens the clock settings, allowing adjustment of year, month, day, hour, minute and second. A built-in clock battery keeps the clock running accurately even when the thermostat loses power, ensuring reliable time-stamped records for the monitoring system.

 

Function Status Indicator Area

Status name Fan operation Winding alarm Winding trip Device failure
Description Indicator lights when the fan is running Indicator lights during a winding over-temperature alarm Indicator lights during a winding over-temperature trip Indicator lights when the device itself fails

Key Region

Key Function
Set key Opens a password input window; enter the correct password (default 13) to access the parameter setting menu
Historical Data key Opens the historical data window to review past temperature records and historical highs
Language toggle key Opens the language selection interface
Manual Fan key Manually starts the fan; the icon background turns green once activated
Alarm mute button Silences the buzzer alarm

Applications

As a dependable temperature monitoring system, the YN-XP502F-3T dry type transformer temperature sensor and controller is widely used in substations, industrial distribution rooms and box-type substations for continuous transformer monitor duties. It helps operators track winding temperature in real time, issue early warnings before overheating occurs, and coordinate fan operation automatically — reducing the risk of outages and equipment damage caused by transformer overheating.

 

A Cost-Effective Alternative to European Imports

Long dominated by manufacturers from Italy, Turkey and other European countries, the dry type transformer temperature monitoring market has relied heavily on imported control units — often meaning longer lead times, higher costs and slower after-sales support. YN-XP502F-3T delivers the same core protection performance your project needs, built and supported locally.

  • Faster delivery — no overseas shipping or customs delays
  • Lower total cost — competitive pricing without compromising reliability
  • Responsive support — direct access to our engineering team, no waiting on overseas agents
  • Flexible customization — channel count, alarm thresholds and communication settings tailored to your project

Looking to replace an imported temperature controller on your next project? Contact us for a side-by-side comparison and full technical documentation →

Prev:

Next:

Inquiry

    Leave a message